UV Systems
Installation and Operating Instructions Models
Model |
| Part # | Part # | |
| (120v/60Hz) | (220v/50Hz) | ||
| 163003 | 163004 | ||
| 163005 | 163006 | ||
| 163007 | 163008 | ||
| 163009 | 163010 | ||
APPLICATION |
|
|
|
|
Ultraviolet Water Disinfection |
|
|
| |
SPECIFICATIONS |
|
|
| |
Models |
| |||
Maximum Operating Pressure | 65 psi | 65 psi | 65 psi | 65 psi |
| (4.5 bar) | (4.5 bar) | (4.5 bar) | (4.5 bar) |
Temperature Range | ||||
Flow Rate @ 60 psi (4.1 bar) | 1 gpm | 2 gpm | 8 gpm | 15 gpm |
| (3.8 Lpm) | (7.6 Lpm) | (30 Lpm) | (56 Lpm) |
Voltage (Domestic) | 120v/60Hz | 120v/60Hz | 120v/60Hz | 120v/60Hz |
Voltage (International) | 220v/50Hz | 220v/50Hz | 220v/50Hz | 220v/50Hz |
CBU Cartridge |
|
|
|
|
The
GENERAL PRECAUTIONS
WARNING: Always disconnect the UV from the power source. Follow the procedures provided in this manual. Improper handling can result in death or serious injury.
WARNING: Do not look directly at the UV lamp. This can cause retina/eye damage.
WARNING: Do not touch the UV bulb. Any fingerprints or dirt will reduce the efficiency of the bulb and may cause it to explode. WARNING: Observe caution when inserting quartz sleeve to prevent breakage and cracking, which may result in injury and damage to unit. NOTE: When handling the UV bulb hold only the
CAUTION: If water pressure exceeds 65 psi, a pressure regulator, set at less than 65 psi, must be installed before the Ultraviolet system. CAUTION: Install on cold water lines only.
CAUTION: Do not install where system is exposed to direct sunlight.
CAUTION: Do not use wicking or sealing agents for fitting connections. Teflon® tape is recommended.
CAUTION: This system must be protected from freezing which can cause cracking of the filter housing and water leakage.
CAUTION: Because of the product’s limited service life, and to prevent costly repairs or possible water damage, we strongly recommend that the bottom of all opaque housings be replaced every ten years. If the bottom of your housing has been in use for more than this period, it should be replaced immediately. Date the bottom of any new or replace- ment housing to indicate the next recommended replacement date. NOTE: Filter cartridge life varies depending on filter type, usage and water conditions.
ASSEMBLY INSTRUCTIONS
See exploded assembly drawings on pages 2 and 3.
CARTRIDGE REPLACEMENT (for UVS-110 and UV-110 only)
Your cartridge should be replaced when there is a noticeable drop in water flow at the faucet or tap, and/or when unpleasant odors return (approximately every
1.Turn off water supply to the system.
2.Open faucet to relieve water pressure to the housing.
3.Unscrew housing from cap. If housing sticks or is difficult to open use an Pentek spanner wrench.
4.Remove used cartridge from housing, remove Teflon® sleeve and dis- card cartridge.
5.Remove
6.Insert a new cartridge into the sump making sure that it slips down over the sump standpipe.
7Remove gasket from cartridge end and slide Teflon® sleeve into cen- ter of cartridge then replace gasket on top of cartridge.
8.Screw the sump onto the cap and
9.Turn on the water supply to allow the unit to slowly fill with water.
10.Check for leaks before leaving installation.
Each time that you use water from your unit for drinking or cooking pur- poses, it is recommended that you run (flush) the tap for at least 10 sec- onds prior to using water. This is particularly important if the water tap is not used daily.
UV LAMP REPLACEMENT
1.Turn off all electrical power to the system by unplugging or throwing the circuit.
2.Unscrew the UV control module from the mounting bracket (4 screws) for Models
For Model
3.Slide the old bulb out and unplug from the control module.
NOTE: Hold the UV lamp only by the plastic covered ends of the bulb.
4.Carefully discard the old UV lamp.
5.Holding the new UV lamp only by the plastic covered ends of the bulb, plug the new UV lamp into the control module or power cord. Slide the new bulb into the cartridge housing and reattach UV control module or secure mounting bracket retainer (depending on model).
6.Restore electrical power to unit.
7.Check for leaks.
For the UVS-110 and UV-110
Allow a minimum of 12 inches clearance under the filter for changing the cartridge, and above the system to allow the UV bulb to be changed.
For the UV-120 and UVBB-120
Allow a minimum of 20 inches clearance under the filter for changing the cartridge, and above the system to allow the UV bulb to be changed.