Intelligent Variable Speed Pump

IntelliFlo® VS+SVRS

Intelligent Variable Speed Pump

Reliable anti-body entrapment protection for your peace of mind

With its built-in controller, proprietary software, and backup safety features, IntelliFlo VS+SVRS pump provides the protection your pool or spa requires with a virtually fail-safe, tamper-proof solution.

Safety Features

Meets ASME A112.19.17 standards, thus complying with

the Virginia Graeme Baker Pool Safety Act SVRS Requirements.

Includes a built-in controller with proprietary software that detects blockage and automatically shuts itself down within seconds.

No SVRS calibration required: the blockage detection/shut down function is pre-programmed into the software. Once the IntelliFlo VS+SVRS pump is installed, the SVRS function works without measurements, calculations and sensitivity settings required with other devices.

Unlike other devices, IntelliFlo VS+SVRS pump’s SVRS protection cannot be disabled.

If for any reason IntelliFlo VS+SVRS pump’s controller becomes inoperable, the pump will not run, providing an added layer of safety.

Safety lock-out feature (password protected) prevents settings from being changed by unauthorized personnel.

The Virginia Graeme Baker Pool & Spa Safety Act of 2007—Summary

This new federal law was enacted to help prevent suction entrapment injuries and becomes effective December 19, 2008. The requirements for public swimming pools, spas, and wading pools are summarized below and must be met before these facilities can be operated after that date.

Drain Cover Requirements - New drain covers certified to ASME/ANSI A112.19.8–2007 must be installed.

Backup System Requirements - Suction piping for each pump must be inspected and will be considered in compliance with the federal law if:

1)no submerged drains connect to the pump, or 2) there are two drains at least 3 feet apart, or 3) there is a single “unblockable” drain. An unblockable drain includes a sump under the cover that is larger than 18 inches by 23 inches, or a channel type drain with a diagonal open area of at least 29 inches.

Single-and two-drain systems less than 3 feet apart that fail to meet one of the above requirements must be updated by adding,

1)Safety Vacuum Release System (SVRS), 2) Suction-Limiting Vent System, 3) Gravity Drainage System, 4) Automatic Pump Shut-Off System, 5) Drain Disablement, or 6) Other Systems determined by Consumer Product Safety Commission to be equally effective. Another option is to split the single drain into a dual-drain system with at least 3 feet of separation.

For more information about the Virginia Graeme Baker Pool and Spa Safety Act and how to comply, review the U.S. Consumer Product Safety Commission’s interpretation posted at: http://www.cpsc.gov/phth/vgpsa.pdf.