Adjustment

7.03

List of parameters

The operator has free access to the "100" parameters. Parameters "200" - "800" can only be changed after entering a code number and may only be changed by authorised personnel.

 

Group

Parameter

Description

Setting range

Set value

 

 

 

 

 

 

 

1

102

Reversing

OFF - ON

OFF

 

 

 

 

 

 

 

 

113

Beep tone for section change

OFF - ON

OFF

 

 

 

 

 

 

 

 

114

Max. speed forwards at each pedal positio

OFF - ON

OFF

 

 

 

 

 

 

 

2

201

Machine configuration

 

 

 

 

 

9 = 487-918/15

 

 

 

 

 

10 = 5487-918/15

 

 

 

 

 

11 = 489-918/15

 

 

 

 

 

 

 

 

 

 

209

Fullness adjustment value (keyboard)

0 - 9

0

 

 

 

 

 

 

 

 

212

Not speed variation with change of fullness

OFF - ON

OFF

 

 

 

 

 

 

 

 

213

program interruption with pedal-position -2

OFF - ON

OFF

 

 

 

 

 

 

 

3

301

Position

0 - 127

0

 

 

 

"Needle point at top edge needle plate"

 

 

 

 

 

(P320ED)

 

 

 

 

 

 

 

 

 

 

302

Position "take-up lever t.d.c."

0 - 127

 

 

 

 

487, 489

 

113

 

 

 

5487

 

107

 

 

 

 

 

 

 

 

303

Position "needle lowered"

0 - 127

 

 

 

 

487, 489

 

24

 

 

 

5487

 

60

 

 

 

 

 

 

 

 

304

Reversing position

0 - 127

113

 

 

 

 

 

 

 

4

401

Delay time "lift foot" (s)

0,01s - 1,5s

0,02s

 

 

 

 

 

 

 

 

402

Start delay after "lower foot" (s)

0,01s - 1,5s

0,15s

 

 

 

 

 

 

 

 

403

Thread cutting time (on the 5487)

0,01s - 0,2s

0,15s

 

 

 

 

 

 

 

 

404

Time for cleaning thread monitor (s)

0,01s - 1,5s

0,25s

 

 

 

 

 

 

 

5

501

Maximum speed

100 - 5500

 

 

 

 

487, 489

 

4800

 

 

 

5487

 

5500

 

 

 

 

 

 

 

 

504

Speed soft start

100 - 5500

1500

 

 

 

 

 

 

 

 

505

Soft start stitches

0 - 15

0

 

 

 

 

 

 

 

 

 

 

 

 

46