Adjustment
Group | Parameter | Description | Setting range | Set value |
|
|
|
|
|
8 | 801 | Right of access function group 100 | 0 - 1 | 0 |
|
|
|
|
|
| 802 | Right of access function group 200 | 0 - 1 | 1 |
|
|
|
|
|
| 803 | Right of access function group 300 | 0 - 1 | 1 |
|
|
|
|
|
| 804 | Right of access function group 400 | 0 - 1 | 1 |
|
|
|
|
|
| 805 | Right of access function group 500 | 0 - 1 | 1 |
|
|
|
|
|
| 806 | Right of access service | 0 - 1 | 1 |
|
|
|
|
|
| 807 | Right of access function group 700 | 0 - 1 | 1 |
|
|
|
|
|
| 808 | Right of access function group 800 | 0 - 1 | 1 |
|
|
|
|
|
| 809 | Right of access program creation | 0 - 1 | 1 |
|
|
|
|
|
| 810 | Enter access code | 0 - 9999 | 3800 |
|
|
|
|
|
7.04 | Sewing motor errors | ||
|
|
|
|
|
| Message | Description |
|
|
|
|
|
| 33 | Invalid parameter value ▲ |
|
| 34 | Brake path too short * |
|
|
|
|
|
| 35 | Communication error with limit control ▲* |
|
| 36 | Switch on sequence not ready ▲* |
|
| 37 | Too many commands ▲ |
|
| 64 | Mains off during initialisation ▲ |
|
| 65 | Overcurrent directly after mains on ▲* |
|
| 66 | Short circuit ▲* |
|
| 68 | Overcurrent during operation ▲* |
|
| 69 | No increments * |
|
| 70 | Motor stalling ▲* |
|
| 71 | No incremental plug ▲* |
|
| 73 | Disturbed motor running * |
|
|
|
|
|
| 74 | Incremental transmitter missing for speed increase/reduction ▲ |
|
| 75 | Regulator blocked * |
|
| 170 | Invalid transmission * |
|
|
|
|
|
| 171 | Invalid zero point * |
|
|
|
|
|
| 173 | Motor blocked on first stitch ▲ |
|
| 175 | Starting error ▲* |
|
| 222 |
▲ P320 ED, * P323 MS
48