Adjustment

1.04.14 Stitch length control eccentric

Requirement

When the needle (with maximum stitch length set), coming from TDC, is 3 mm above the needle plate, the crank 3 must have reached its front point of reversal.

1

2

2

3

Fig. 1 - 14

● Set the maximum stitch length.

● lTurn stitch length control device 1 (screws 2) according to the requirement.

23