Adjustment

1.04.15 Stitch length scale disk

Requirement

When the stitch length control device is engaged and the stitch length is set at “0”, the marking line on scale disk 1 should be positioned opposite the lower edge 3 of the guard belt opening.

1

3

2

61-038

Fig. 1 - 15

Set stitch length "0".

Turn stitch length control device 1 (screws 2) according to the requirement.