Adjustment
1.06.07 Releasing the tension
Requirement
When the magnet is activated, tension discs 3 must be at least 0.5 mm apart.
0,5mm
3
1
2
Fig. 1 - 44
● Activate the magnet.
● Detach the tension bearing plate 1 and adjust pressure plate 2 in accordance with the requirement .
It is possible to set the time for releasing the tension with the parameter functions, see Chapter 1.08 Parameter settings.
53