Care and maintenance
10.04.02 | Parameter list for drive system |
|
| ||
|
|
|
|
|
|
|
| Parameter | Description | Setting range | Set value |
|
|
|
|
|
|
|
| 1 | Speed max. | 50 - 9999 | ▲ |
|
|
|
|
|
|
|
| 4 | Speed for start backtackl | 50 - 8000 | 1500 |
|
|
|
|
|
|
|
| 5 | Speed for end backtack | 50 - 8000 | 1500 |
|
|
|
|
|
|
|
| 46 | Rotating direction of the motor | CW - CCW | CW |
|
|
|
|
|
|
|
| 47 | Selected machine class | 0 - 101 | 62 |
|
|
|
|
|
|
|
| 61 | Cutting speed 1 | 50 - 500 | 220 |
|
|
|
|
|
|
|
| 81 | Needle position 6 (start cutting signal 2) | 0 - 360° | 40° |
|
|
|
|
|
|
|
| 84 | Needle position 5 (end cutting signal 1) | 0 - 360° | 90° |
|
|
|
|
|
|
|
| 85 | Needle position 9 (start thread tension | 0 - 360° | 120° |
|
|
| release/start thread catcher) | ||
|
|
|
|
| |
|
|
|
|
|
|
|
| 87 | Tension release after thread lever position at t.d.c. | 0 - 1500ms | 20ms |
|
|
|
|
|
|
|
| 179 | Needle position 2 | 0 - 359° | 83° |
|
|
|
|
|
|
|
| 181 | Needle position 1 - needle lowered (192 = off) | 0 - 255 | 250 |
|
|
|
|
|
|
|
| 210 | Switch on angle for thread trapper | 0 - 359° | 20° |
|
|
|
|
|
|
|
| 211 | Switch off angle for thread trapper | 0 - 359° | 90° |
|
|
|
|
|
|
|
| 236 | Machine version | 0 - 4 | 2 |
|
|
| 2 = 581 + 583 | ||
|
|
|
|
| |
|
|
|
|
|
|
See Chapter 3 Specifications
*Adjustment see Chapter 8.05 Basic position of the machine drive unit.
32