Care and maintenance
10.04 Parameter settings
Parameter settings are described in the separate operations manual for
the drive, and may only be changed by qualifi ed technicians!
10.04.01 | Parameter list for PicoDrive with control unit P41 PD2 |
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| Group | Parameter | Description | User lever |
| Setting range | Set value |
|
|
|
|
|
|
|
| |
|
| 1 | 105 | Speed for start backtackl | B, C | 300 - 2000 | 1500 | |
|
|
|
|
|
|
|
| |
|
|
| 110 | Speed for end backtack | B, C | 300 - 2000 | 1500 | |
|
|
|
|
|
|
|
| |
|
| 6 | 606 | Speed min | B, C | 30 - 300 | 180 | |
|
|
|
|
|
|
|
| |
|
|
| 607 | Speed max. | B, C | 300 - 6000 | ▲ | |
|
|
|
|
|
|
|
| |
|
|
| 609 | Cutting speed 1 | B, C | 60 - 300 | 220 | |
|
|
|
|
|
|
|
|
|
|
|
| 668 | Thread wiper/thread blower | B, C | 0 | - 1 | 0 |
|
|
|
| 1 = on; 0 = off |
|
|
|
|
|
|
|
|
|
|
|
| |
|
| 7 | 700 | Needle position 0 | B, C | 0 | * | |
|
|
|
| (needle reference position |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 702 | Needle position 1 (needle lowered) | B, C | 0 - | 255 | 79 |
|
|
|
|
|
|
|
|
|
|
|
| 703 | Needle position 2 | B, C | 0 - | 255 | 222 |
|
|
|
|
|
|
|
|
|
|
|
| 705 | Needle position 5 (end cutting signal 1) | B, C | 0 - | 255 | 175 |
|
|
|
|
|
|
|
|
|
|
|
| 706 | Needle position 5 (start cutting signal 2) | B, C | 0 - | 255 | 135 |
|
|
|
|
|
|
|
|
|
|
|
| 707 | Needle position 9 (start thread tension | B, C | 0 - | 255 | 190 |
|
|
|
| release/start thread catcher) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 797 | Hardwaretest (OFF / ON ), | B, C |
|
| OFF |
|
|
|
|
|
|
|
|
|
|
|
| 799 | Selected machine class | C | 1 | - 3 | 1 |
|
|
|
|
|
|
|
|
|
|
| 8 | 800 | Rotating direction of the motor | C | 0 | - 1 | 1 |
|
|
|
|
|
|
|
|
|
|
|
| 802 | Main drive reduction ratio | C | 0 | - 1 | 0 |
|
|
|
| 0 = 1:1, 1 = variable |
|
|
|
|
|
|
|
|
|
|
|
| |
|
| 9 | 985 | Switch on angle for thread trapper | B, C | 0 | 67 | |
|
|
|
|
|
|
|
| |
|
|
| 986 | Switch off angle for thread trapper | B, C | 0 | 206 | |
|
|
|
|
|
|
|
|
|
|
|
| 989 | Thread trapper at beginning of seam | B, C | 0 | - 2 | 0 |
|
|
|
| 0 = no |
|
|
|
|
|
|
|
| 1 = yes |
|
|
|
|
|
|
|
| 2 = Thread clamp with sewing foot lift |
|
|
|
|
|
|
|
|
|
|
|
|
|
See Chapter 3 Specifications
*Adjustment see Chapter 8.05 Basic position of the machine drive unit.
31