Care and maintenance

10.04 Parameter settings

Parameter settings are described in the separate operations manual for

the drive, and may only be changed by qualifi ed technicians!

10.04.01

Parameter list for PicoDrive with control unit P41 PD2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Group

Parameter

Description

User lever

 

Setting range

Set value

 

 

 

 

 

 

 

 

 

 

1

105

Speed for start backtackl

B, C

300 - 2000

1500

 

 

 

 

 

 

 

 

 

 

 

110

Speed for end backtack

B, C

300 - 2000

1500

 

 

 

 

 

 

 

 

 

 

6

606

Speed min

B, C

30 - 300

180

 

 

 

 

 

 

 

 

 

 

 

607

Speed max.

B, C

300 - 6000

 

 

 

 

 

 

 

 

 

 

 

609

Cutting speed 1

B, C

60 - 300

220

 

 

 

 

 

 

 

 

 

 

 

 

668

Thread wiper/thread blower

B, C

0

- 1

0

 

 

 

 

1 = on; 0 = off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

700

Needle position 0

B, C

0 -255

*

 

 

 

 

(needle reference position

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

702

Needle position 1 (needle lowered)

B, C

0 -

255

79

 

 

 

 

 

 

 

 

 

 

 

 

703

Needle position 2 (take-up lever raised)

B, C

0 -

255

222

 

 

 

 

 

 

 

 

 

 

 

 

705

Needle position 5 (end cutting signal 1)

B, C

0 -

255

175

 

 

 

 

 

 

 

 

 

 

 

 

706

Needle position 5 (start cutting signal 2)

B, C

0 -

255

135

 

 

 

 

 

 

 

 

 

 

 

 

707

Needle position 9 (start thread tension

B, C

0 -

255

190

 

 

 

 

release/start thread catcher)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

797

Hardwaretest (OFF / ON ),

B, C

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

799

Selected machine class

C

1

- 3

1

 

 

 

 

 

 

 

 

 

 

 

8

800

Rotating direction of the motor

C

0

- 1

1

 

 

 

 

 

 

 

 

 

 

 

 

802

Main drive reduction ratio

C

0

- 1

0

 

 

 

 

0 = 1:1, 1 = variable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

985

Switch on angle for thread trapper

B, C

0 -255

67

 

 

 

 

 

 

 

 

 

 

 

986

Switch off angle for thread trapper

B, C

0 -255

206

 

 

 

 

 

 

 

 

 

 

 

 

989

Thread trapper at beginning of seam

B, C

0

- 2

0

 

 

 

 

0 = no

 

 

 

 

 

 

 

 

1 = yes

 

 

 

 

 

 

 

 

2 = Thread clamp with sewing foot lift

 

 

 

 

 

 

 

 

 

 

 

 

 

See Chapter 3 Specifications

*Adjustment see Chapter 8.05 Basic position of the machine drive unit.