Technical Information for System Engineers
Sequence (MLS) and Time Delay Spectrometry (TDS). Performance, development and data acquisition tools include: Gold Line TEF 20, CLIO, LMS, LEAP, and proprietary modeling software. EASE™ data are acquired through an automated TEF 20/Outline/EASE™ interface.
EASE™ Data –
SoundTubeSPEC™ – Proprietary SoundTube speaker placement software.
Architectural Specifications
The loudspeaker shall consist of a 101 mm (4 in) full range driver.
Performance specifications of a typical production unit shall be as fol- lows: Useable frequency response shall extend from 69 Hz – 22 kHz
70.7& 100 Volt modes with voice coil/8 Ohm direct. Rated power capacity shall be at least 20 Watts continuous power (RMS) and conform to
testing. Maximum continuous output at 1 meter shall be 104.5 dB.
The transducer shall have a treated fiber cone with a treated cloth surround and mated to an ABS baffle.
Installation and safety attachment for the
The enclosure shall be constructed of
The system shall be the SoundTube
SoundTube Entertainment
6430 North Business Park Loop Park City, Utah 84098
Phone 435.647.9555
Fax 435.647.9666 Toll Free 800.647.TUBE www.soundtube.com
All SoundTube products come with a
Polar Plots
125 Hz | 250 Hz | 500 Hz | 1,000 Hz |
2,000 Hz | 4,000 Hz | 8,000 Hz | 10,000 Hz |
Technical data, EASE™ plots, SoundTubeSPEC™ software & product downloads available at www.soundtube.com