Philips Lighting Company | www.philips.com | Philips Lighting |
200 Franklin Square Drive |
| 281 Hillmount Road |
P.O.Box 6800 |
| Markham, Ontario |
Somerset, NJ |
| Canada L6C 2S3 |
| ||
A Division of Philips Electronics North America Corporation | A Division of Philips Electronics Ltd. | |
Updated 5/09 |
|
MasterColor® CDM Elite MW 315 Watt 4200K T9 (Clear) Lamp
Electrical Data (Subject to change without notice)
Lamp Watts (Nominal) | 315 |
Lamp Operating Voltage (rms) (Nominal)4 | 100 |
Initial Lamp Voltage Range (rms)5 | |
Lamp Operating Current (Amps) (rms) (Nominal) | 3.15 |
<3 Minutes | |
10 Minutes | |
Ballast Type | Electronic, ANSI C182/E |
Ballast Open Circuit Voltage (Minimum) | 260V |
Ignition Burst Height (Maximum) | 4K V |
Minimum Operating Temperature | |
|
|
1)Measured at 100 hrs of life in vertical position.
2)Approximate lumen output at 40% of lamps rated average life.
3)Rated average life is obtained at 50% survival rate.
4)Measured at rated lamp watts on a linear reactor or electronic ballast. LPW does not include ballast losses.
5)Measured with the lamp operating at rated watts.
Warnings, Cautions and Operating Instructions
R“WARNING: These lamps can cause serious skin burn and eye inflammation from short wave
punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. Certain lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available.”This lamp complies with FDA radiation performance standard 21 CFR subchapter J. (USA: 21CFR 1040.30
If the outer bulb is broken or punctured,turn off at once and replace the lamp to avoid possible injury from hazardous short wave ultraviolet radiation. Do not scratch the outer bulb or subject it to pressure as this could cause the outer bulb to crack or shatter.A partial vacuum in the outer bulb may cause glass to fly if the envelope is struck.
WARNING: The
DAMAGE, BURNS AND FIRE.
Certain lamps that will retain all the glass particles should inner
RELAMP FIXTURES AT OR BEFORE THE END OF RATED LIFE. Allowing lamps to operate until they fail is not advised and may increase the possibility of inner arc tube rupture.This lamp contains an arc tube with a filling gas containing less than 25 nCi of
CAUTION: TO REDUCE THE RISK OF PERSONAL INJURY,PROPERTY DAMAGE, BURNS AND FIRE RESULTING FROM AN
Lamp Operating Instructions:
1.Relamp fixtures at or before the end of rated life.Allowing lamps to operate until they fail is not advised and may increase the possibility of inner arc tube rupture.
2.Use only in an enclosed fixture capable of withstanding particles of glass having temperatures up to 1000°C.
3.Before lamp installation/replacement, shut power off and allow lamp and fixture to cool to avoid electrical shock and potential burn hazards.
4.Use only auxiliary equipment meeting Philips and/or ANSI standards. Use within voltage limits recommended by ballast manufacturer.
A.Operate lamp only within specified limits of operation.
B.For total supply load refer to ballast manufacturers electrical data.
C.All Pulse Start lamps require a socket rated to withstand a 4,000 volt pulse
5.Periodically inspect the outer envelope. Replace any lamps that show scratches, cracks or damage.
6.If a lamp bulb support is used, be sure to insulate the support electrically to avoid possible decomposition of the bulb glass.
7.Protect lamp base, socket and wiring against moisture, corrosive atmospheres and excessive heat.
8.Time should be allowed for lamps to stabilize in color when turned on for the first time.This may require several hours of operation, with more than one start. Lamp color is also subject to change under conditions of excess vibration or shock, and color appearance may vary between individual lamps.
9.Lamps may require 10 minutes to
10.Take care in handling and disposing of lamps. If an arc tube is broken, avoid skin contact with any of the contents or fragments.
11.Use this lamp only in fixtures that contain a Pulse Start metal halide ballast and are specifically designed for use with Pulse Start metal halide lamps.