Pulse Start Metal Halide 400 Watt Lamp (Clear)
Electrical Data (Subject to change without notice)
Lamp Watts (Nominal) | 400 |
Lamp Operating Voltage (rms) (Nominal)3 | 132 |
Initial Lamp Voltage Range (rms)6 | 120 |
Lamp Operating Current (Amps) (rms) (Nominal) . . . . | 3.25 |
Lamp Current Crest Factor (Maximum) | 1.6 |
3 Minutes | |
4 Minutes | |
Ballast Type | ANSI M135/M128/S |
Ballast Open Circuit Voltage (Minimum) | 245 RMS Min. |
Pulse Peak Volts | 3000 Min., 4000 Max. |
Pulse Width @ 90% Peak (micro sec) | 1.3 |
Pulse Repetition Rate (Minimum) | 2x/1/2cycle |
Minimum Operating Temperature | |
Advance Transformer Ballast Number | 71A6092 |
|
|
1)Approximate lumen values listed are for vertical operation of the lamp.
2)Measured at 100 hours of life in vertical position.
3)Measured at rated lamp watts on a linear reactor. LPW does not include ballast losses.
4)Approximate lumen output at 40% of lamp rated average life.
5)Rated average life is the life obtained, on the average, from large representative groups of lamps in laboratory tests under controlled conditions at 10 or more operating hours per start. It is based on survival of at least 50% of the lamps and allows for individual lamps or groupls of lamps to vary considerably from the average.
6)Measured with the lamp operating at rated watts.
Warnings, Cautions and Operating Instructions
“WARNING:These lamps can cause serious skin burn and eye inflammation from short wave ultraviolet radiation if outer envelope of the lamp is broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. Certain lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available." This lamp complies with FDA radiation performance standard 21 CFR subchapter J. (USA:21CFR 1040.30
If the outer bulb is broken or punctured, turn off at once and replace the lamp to avoid possible injury from hazardous short wave ultraviolet radiation. Do not scratch the outer bulb or subject it to pressure as this could cause the outer bulb to crack or shatter.A partial vacuum in the outer bulb may cause glass to fly if the envelope is struck.
WARNING: The
DAMAGE, BURNS AND FIRE.
Certain lamps that will retain all the glass particles should inner
RELAMP FIXTURES AT OR BEFORE THE END OF RATED LIFE. Allowing lamps to operate until they fail is not advised and may increase the possibility of inner arc tube rupture.
CAUTION: TO REDUCE THE RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE RESULTING FROM AN
Lamp Operating Instructions:
1)Turn off lamps at least once a week for at least 15 minutes in systems which are operating on a continuous basis (24
2)RELAMP FIXTURES AT OR BEFORE THE END OF RATED LIFE.Allowing lamps to operate until they fail is not advised and may increase the possibility of inner arc tube rupture.
3)If operated other than vertical ± 15º, use only in an enclosed fixture capable of withstanding particles of glass having temperatures up to 1000ºC unless otherwise noted.
4)Before lamp installation/replacement, shut power off and allow lamp and fixture to cool to avoid electrical shock and potential burn hazards.
5)Use only auxiliary equipment meeting Philips and/or ANSI standards. Use within voltage limits recommended by ballast manufacturer.
A.Operate lamp only within specified limits of operation.
B.For total supply load refer to ballast manufacturers electrical data.
C.All Pulse Start mogul based lamps require a socket rated to withstand a 4000 volt pulse.
6)Periodically inspect the outer envelope. Replace any lamps that show scratches, cracks or damage.
7)If a lamp bulb support is used, be sure to insulate the support electrically to avoid possible decomposition of the bulb glass.
8)Protect lamp base, socket and wiring against moisture, corrosive atmospheres and excessive heat.
9)Time should be allowed for lamps to stabilize in color when turned on for the first time.This may require several hours of operation, with more than one start. Lamp color is also subject to change under conditions of excess vibration or shock, and color appearance may vary between individual lamps.
10)Lamps may require 2 to 4 minutes to
11)Take care in handling and disposing of lamps. If an arc tube is broken, avoid skin contact with any of the contents or fragments.
12)Use this lamp only in fixtures that contain a Pulse Start metal halide ballast and are specifically designed for use with Pulse Start metal halide lamps.