MasterColor® Ceramic Metal Halide 22 Watt 3000K
Electrical Data (Subject to change without notice )
Lamp Watts (Nominal) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Lamp Operating Voltage (rms) (Nominal)2. . . . . . . . . . . . . 100
Initial Lamp Voltage Range (rms)3. . . . . . . . . . . . . . . . . . . . .
Lamp Operating Current (Amps) (rms) (Nominal) . . . . . 0.22
Lamp Current Crest Factor (Maximum) . . . . . . . . . . . . . . 1.8
Restrike Time for Hot Lamp. . . . . . . . . . . . . . . . . . . . . . . . .
Ballast Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C156/C175/E
Ballast Open Circuit Voltage (Minimum). . . . . . . . . . . . . . . 250
Pulse PeakVolts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3000 Min., 4000 Max.
Pulse Width @ 90% Peak . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Micro Second Min.
Pulse Repetition Rate (Minimum)4 . . . . . . . . . . . . . . . . . . . . 1 per Half Cycle
Minimum Operating Temperature. . . . . . . . . . . . . . . . . . . .
1)Measured at 100 hours of life in vertical position.
2)Measured at rated lamp watts on a linear reactor. LPW does not include ballast losses.
3)Measured with the lamp operating at rated watts.
4)
INSTALLATION INFORMATION
MasterColor® Metal Halide T4 lamps must be used in combination with appropriate fully electronic ballast.
Warnings, Cautions and Operating Instructions
R“WARNING:These lamps can cause seriousskin burn and eye inflammation from short waveultravioletradiationif outer envelopeof the lamp is brokenor punctured.Do not use where people will remainfor more than a few minutesunless
adequateshieldingor other safetyprecautionsare used.Certainlamps that will automaticallyextinguishwhen the outer envelopeis brokenor puncturedare commerciallyavailable." This lamp complieswith FDA radiationperformance standard21 CFR subchapterJ.
If the outer bulb is brokenor punctured,turn off at once and replace the lamp to avoid possible injury from hazardousshort wave ultraviolet radiation.Do not scratch the outer bulb or subject it to pressureas this could cause the outer bulb to crack or shatter.A partial vacuum in the outer bulb may cause glass to fly if the envelopeis struck.
WARNING:The
DAMAGE,BURNSAND FIRE.
Certain lamps that will retain all the glass particles should inner
RELAMP FIXTURESATOR BEFORETHE END OF RATEDLIFE. Allowinglamps to operateuntil they fail is not advisedand may increase the possibilityof inner arc tube rupture.
This lamp contains an arc tube with a filling gas containing less than
10 nCi of
New Jersey,08875.
CAUTION: TO REDUCETHE RISK OF PERSONALINJURY,PROPERTY DAMAGE,BURNSAND FIRE
Lamp Operating Instructions:
1) RELAMP FIXTURES AT OR BEFORE THE END OF RATED LIFE. Allowing lamps to operate until they fail is not advised and may increase the possibility of inner arc tube rupture.
2)Use only in fully enclosed fixtures capable of withstanding particles of glass having temperatures up to 1000°C. Lens/diffuser material must be heat resistant. Consult fixture manufacturer regarding the suitability of the fixture for this lamp.
3)Do not operate a fixture with a missing or broken lens/diffuser.
4)Operate lamp only within specified limits of operating position.
5) Before lamp installation/replacement, shut power off and allow lamp and fixture to cool to avoid electrical shock and potential burn hazards.
6)Use only auxiliary equipment meeting Philips and/or ANSI standards. Use within voltage limits recommended by ballast manufacturer.
A.Operate lamp only within specified limits of operation.
B.For total supply load refer to to ballast manufacturer’s electrical data.
C.Operate
D.Operate
7)Periodically inspect the outer envelope. Replace any lamps that show scratches, cracks or damage.
8)If a lamp bulb support is used, be sure to insulate the support electrically to avoid possible decomposition of the bulb glass.
9)Protect lamp base, socket and wiring against moisture, corrosive atmospheres and excessive heat.
10)Time should be allowed for lamps to stabilize in color when turned on for the first time. This may require several hours of operation, with more than one start. Lamp color is also subject to change under conditions of excess vibration or shock, and color appearance may vary between individual lamps.
11)Lamps may require
12)Take care in handling and disposing of lamps. If an arc tube is broken, avoid skin contact with any of the contents or fragments.