ML

High Pressure Mercury

.-&

More efficient than incandescent

Applications

r Public outdoor lighting, car parks, workshops, garages and shops

Why choose?

r Direct retrofit for incandescent lamps

r Higher efficacy and lifetime than incandescent

Technical Features

r High-pressure mercury tube in series with a tungsten filament

r Runs on mains voltage without additional gear

r Combines a continuous spectrum from the incandescent source and a line spectrum from the high-pressure mercury source

r It is recommended to protect ML against water splashes

r ML lamps are not dimmable

ML

High Pressure Mercury

Dimensions in mm

C

D

 

max.

max.

160W B22

165



8&

154



8&





8&

216

90

250W E40

226

90

500W E40

289

120

.-&&

ML B22

Burning Burning

positions positions

Operational

position

ML 100 W ML

ML 250 W ML

160 W

500 W

 

 

Universal

Preferred selection

Product ID

lamp

Packaging

Soft Glass/

Colour

Colour

Luminous

Order Code

 

Base

Configuration

Hard glass

Rendering

Temperature

flux lamp EM

 

 

 

 

 

 

Index (Ra)

(K)

(lm)

 

ML100W

&

24

 

SG



3300

1100



ML160W

B22

24

 

SG

65

3600

3150

9286 010 11401

ML160W

&

24

 

SG

65

3600

3150

9286 010 08988

ML250W

&

12

 

SG

65

3400

5400

9280 960 56898

ML250W

E40

12

 

HG

65

3400

5400



ML250W

E40

12

 

SG

65

3400

5400

9286 010 09288

ML500W

E40

6

 

HG

48



13000



Product ID

Voltage

Bulb

Lamp Current

Luminous Efficacy

Net weight

Ignition Supply

 

 

 

Finish

EM (A)

lamp EM

 

per piece

Voltage

 

 

 

 

 

(Lm/W)

 

(g)

min. (V)

ML100W

220-230V

coated

0.46

10.5

 

52

180

ML160W

220-230V

coated



19

 

64

180

ML160W

220-230V

coated



19

 

61

180

ML250W

225-235V

coated

1.2

21

 

184

180

ML250W

220-230V

coated

1.2

21

 

184

180

ML250W

220-230V

coated

1.2

21

 

184

180

ML500W

220-230V

coated

2.3

26

 

230

180

ML500W

225-235V

coated

2.3

26

 

230

180

 

 

 

 

 

 

 

 

 

2.6.13

 

 

 

 

 

 

 

HIGH INTENSITY DISCHARGE LAMPS - LAMPS 2.6.14

 

 

 

 

Page 78
Image 78
Philips Compact Fluorescent Integrated Lamps manual &, ML B22, Burning Burning Positions positions Operational