
Philips Lighting Company | www.philips.com | Philips Lighting |
200 Franklin Square Drive |
| 281 Hillmount Road |
P.O. Box 6800 |
| Markham, Ontario |
Somerset, NJ |
| Canada L6C 2S3 |
| ||
A Division of Philips Electronics North America Corporation | A Division of Philips Electronics Ltd. | |
Updated 09/05 |
|
Ceramalux® High Pressure Sodium
Featuring ALTO® Lamp Technology
Lamp Watts (Nominal) . . | . . . | . . . . . | . | . . . . . | . | . . . . | . . | . . . | 100 |
|
| ||
Lamp Operating Voltage (rms) (Nominal)3 . | . | . . . . | . . | . . . | 65 |
|
|
| |||||
Initial Lamp Voltage Range (rms)6 . . | . | . . . . . | . | . . . . | . . | . . . |
|
|
| ||||
Lamp Operating Current (Amps) (rms) (Nominal) . . . . | 2.1 |
|
| ||||||||||
Maximum Lamp Starting Current (Amps) (rms) . | . . | . . . | 3.2 |
|
| ||||||||
Lamp Current Crest Factor (Maximum) . . | . | . . . . | . . | . . . | 1.8 |
|
| ||||||
. | . . . . . | . | . . . . | . . | . . . | 5 Minutes | |||||||
Restrike Time for Hot Lamp | . | . . . . . | . | . . . . | . . | . . . | 5 Minutes | ||||||
Ballast Type | . . . | . . . . . | . | . . . . . | . | . . . . | . . | . . . | ANSI S54 | ||||
Ballast Open Circuit Voltage (Minimum) . . | . | . . . . | . . | . . . | 110 |
|
| ||||||
Pulse Peak Volts | . . . | . . . . . | . | . . . . . | . | . . . . | . . | . . . | 2500 Min., 4000 Max. | ||||
Pulse Width @ 90% Peak | . . . | . . . . . | . | . . . . . | . | . . . . | . . | . . . | 1 Micro Second Minimum | ||||
Pulse Frequency (Minimum) |
|
|
|
|
|
|
|
|
|
| |||
Lag Ballast | . . . | . . . . . | . | . . . . . | . | . . . . | . . | . . . | 1 per Cycle | ||||
Lead Circuit Ballast | . . . | . . . . . | . | . . . . . | . | . . . . | . . | . . . | 1 per Half Cycle | ||||
Minimum Operating Temperature. . | . | . . . . . | . | . . . . | . . | . . . |
|
| |||||
Reference Ballast Impedance | . | . . . . . | . | . . . . | . . | . . . | 44 Ohms at 120V RIV | ||||||
Maximum Lamp Watts . . | . . . | . . . . . | . | . . . . . | . | . . . . | . . | . . . | 124 |
|
| ||
Minimum Lamp Watts . . . | . . . | . . . . . | . | . . . . . | . | . . . . | . . | . . . | 72 |
|
|
| |
Maximum Voltage Increase by Fixture . . . . | . | . . . . | . . | . . . | 4 |
|
|
| |||||
Approximate Lumen Maintenance Curve | |||||||||||||
| for ALTO NC HPS Lamps: |
|
| ||||||||||
Lumens | 100 |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| ||||
90 |
|
|
|
|
|
|
|
|
|
|
| ||
Initial |
|
|
|
|
|
|
|
|
|
|
| ||
80 |
|
|
|
|
|
|
|
|
|
|
| ||
Approx.– |
|
|
|
|
|
|
|
|
|
|
| ||
70 |
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| ||
Percent | 60 |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| |||
0 |
|
|
|
|
|
|
|
|
|
|
| ||
20 | 40 | 60 | 80 | 100 | |||||||||
| %0 |
Percent of Rated Average Life4
Approximate Survival Curve for ALTO NC HPS Lamps:
100
Lumens | 90 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
80 |
|
|
|
|
|
|
| |
Initial |
|
|
|
|
|
|
| |
70 |
|
|
|
|
|
|
| |
Approx.– |
|
|
|
|
|
|
| |
60 |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
Percent | 50 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
0 |
| 20 | 40 | 60 | 80 | 100 | ||
| %0 |
Percent of Rated Average Life4
Footnotes:
1)Measured at 100 hrs. life. Approximate lumen values listed are for vertical or horizontal operation of lamp.
2)Approximate mean lumen output at 40% of lamp rated average life.
3)Measured at rated lamp watts on a linear reactor. LPW does not include ballast losses.
4)Rated average life is the life obtained, on the average, from large representative groups of lamps in laboratory tests under controlled conditions at 10 or more operating hours per start. It is based on survival of 65% of the lamps and allows for individual lamps or groups of lamps to vary considerably from the average.
5)Approximate color temperature in Kelvin degrees.
6)Measured with the lamp operating at rated watts. Measured lamp voltage will change as the ballast changes lamp wattage.
* The TCLP is the US EPA’s Toxicity Characteristic Leaching Procedure
WARNINGS,CAUTIONS AND OPERATING INSTRUCTIONS for Ceramalux High Pressure Sodium Lamps
R“WARNING: These lamps must be operated in fixtures designed for use with High Pressure Sodium lamps.The fixture wattage rating must match the wattage indicated on the outer glass bulb. Do not scratch the outer bulb or subject it to pressure as this
could cause the outer bulb to crack or shatter. A partial vacuum in the outer bulb may cause glass to fly if the glass is struck. Operating the lamp improperly may result in
PERSONAL INJURY,PROPERTY DAMAGE, BURNS AND FIRE.
1)If the outer glass bulb is broken, shut off power immediately and remove the lamp after it has cooled.
2)Use only auxiliary equipment meeting Philips and/or ANSI standards. Use within voltage limits recommended by ballast manufacturer.
A.Operate lamp only within specified limits of operation.
B.For total supply load refer to ballast manufacturers electrical data.
3)Protect lamp base, socket and wiring against moisture, corrosive atmospheres and excessive heat.
4)Replace the lamp if the outer glass bulb has been scratched, cracked or damaged in any way.
5)If a lamp bulb support is used, be sure to insulate the support electrically so as to avoid possible decomposition of the bulb glass.
6)Do not use this lamp in a fixture which redirects a substantial portion of the energy toward the arc tube and its immediate vicinity, as this may lead to very early lamp failure.
7)Take care in handling and disposing of lamps. If arc tube is broken, avoid skin contact with any of the contents or fragments.
8)The arc tube of this lamp contains sodium and mercury. Dispose of in accordance with federal, state and local requirements.