34 / 58
7 Registers management

Memory Organization

The user must know that a new register value sent through the
communication port is loaded to the running parameters in RAM and used
for the current process. All these parameters are lost upon power-down. It
is required to save them to “User Parameters” or “Factory Parameters” with
the corresponding function.
NON VOLATILE DATA.
EEPROM EEPROM ROM
USER Parameters
Saved
FACTORY Parameters
Saved
SOS IP
address
5
1 2 3 4
VOLATILE DATA.
RAM
RUNNING
WRITE
Parameters
READ
PROCESSES
Communication port
(TCP/UDP)
[Web page or Software]
Action Number and description:
1 SaveUserParameters (0x03) function
During standard power-up or calling
2 RestoreUserParameters (0x04) function
3 RestoreFactoryParameters (0x05) function
SaveFactoryParameters (0x06) function
+ 1 4 [For integrators engineers only]
5 By setting “SOS Jumper” after power-up
3 5
+ + 1 By setting “SOS Jumper” during power-up
FMod-TCP User Manual v.2.8