Philips PLUS T8 High Output 8-Foot Fluorescent Lamps featuring ALTO® Lamp Technology Ordering, Electrical andTechnical Data (Subject to change without notice)

 

 

 

Nom.

Rated Average Life (Hrs.)1

Approx.

 

 

 

 

Product

Ordering

Pkg.

Length

3-Hr.

12-Hr.

Initial

Design

CCT

 

Lumen

Number

Code

Qty.

(In.)

Start2

Start3

Lumens4

Lumens5

(Kelvin)

CRI

Maintenance

38826-4

F96T8/TL830/HO/PLUS/ALTO

24

96

24,000

30,000

8200

7625

3000K

85

95%

38827-2

F96T8/TL835/HO/PLUS/ALTO

24

96

24,000

30,000

8200

7625

3500K

85

95%

38828-0

F96T8/TL841/HO/PLUS/ALTO

24

96

24,000

30,000

8200

7625

4100K

85

95%

38831-4

F96T8/TL741/HO/PLUS/ALTO

24

96

24,000

30,000

7900

7100

4100K

78

95%

 

 

 

 

 

 

 

 

 

 

 

1)Rated average life is the length of operation (in hours) at which point an average of 50% of a large sample of lamps will still be operational and 50% will not.

2)Average life under specified test conditions with lamps turned off and restarted no more frequently than once every 3 operating hours. Lamp life is appreciably longer if lamps are started less frequently.

3)Average life under engineering data with lamps turned off and restarted once every 12 operating hours.

4)Approximate initial lumens.The lamp lumen output is based upon lamp performance after 100 hours of operating life, when the output is measured during operation on a reference ballast under standard laboratory conditions. For expected lamp lumen output, commercial ballast manufacturers can advise the appropriate ballast factor for each of their ballasts when they are informed of the designated lamp.The ballast factor is a multiplier applied to the designated lamp lumen output.

5)Design lumens are the approximate lamp lumen output at 40% of the lamp’s rated average life.This output is based upon measurements obtained during lamp operation on a reference ballast under standard laboratory conditions.

Lamp meets US Federal Minimum Efficiency Standards.

Rated Average Life1

Philips PLUS T8 High Output 8-Foot Fluorescent Lamps

BASED ON 3 HOURS PER START2

24,000

BASED ON 12 HOURS PER START3

30,000

0

5,000

10,000

15,000

20,000

25,000

30,000

Rated Average Life in Hours

For footnotes 1, 2 and 3, see above

Footnotes from front page:

Average life under engineering data with lamps turned off and restarted once every 12 operating hours.

‡ The TCLP is the US EPA’s Toxicity Characteristic Leaching Procedure.

© 2008 Philips Lighting Company. All rights reserved. Printed in USA 6/08

P-5029-E

www. philips.com

Philips Lighting Company

Philips Lighting

200 Franklin Square Drive

281 Hillmount Road

P.O. Box 6800

Markham, Ontario

Somerset, NJ 08875-6800

Canada L6C 2S3

1-800-555-0050

1-800-555-0050

A Division of Philips Electronics North America Corporation

A Division of Philips Electronics Ltd.