Philips P-5338-G Ordering, Electrical andTechnical Data, 95% Lumen Maintenance Rated Average Life

Models: P-5338-G

1 2
Download 2 pages 37.57 Kb
Page 2
Image 2

PhilipsT8 Lamps featuring ALTOIITechnology

Ordering, Electrical andTechnical Data

*

*

*

*

*

*

*

*

*

*

*

*

*

*

E

E

E

E

*E

*E

*E

*E

*E

 

 

 

 

Color

Nom.

Rated Average Life (hrs)1

Approx.

 

 

 

Product

Ordering

 

Pack.

Temp.

Length

12-hr on

12-hr on

Initial

Design

 

Lumen

Number

Code

Watts

Qty.

(Kelvin)

(In.)

Ins. Start

Prog. Start

Lumens2

Lumens3

CRI

Maint.

36787-0

F17T8/TL830/ALTO

17

25

3000

24

30,000

36,000

1400

1330

85

95%

36791-2

F17T8/TL835/ALTO

17

25

3500

24

30,000

36,000

1400

1330

85

95%

36793-8

F17T8/TL841/ALTO

17

25

4100

24

30,000

36,000

1400

1330

85

95%

14123-4

F17T8/TL850/ALTO

17

25

5000

24

30,000

36,000

1325

1260

82

95%

36807-6

F17T8/TL730/ALTO

17

25

3000

24

30,000

36,000

1325

1260

78

95%

36808-4

F17T8/TL735/ALTO

17

25

3500

24

30,000

36,000

1325

1260

78

95%

36812-6

F17T8/TL741/ALTO

17

25

4100

24

30,000

36,000

1325

1260

78

95%

36813-4

F25T8/TL830/ALTO

25

25

3000

36

30,000

36,000

2225

2115

85

95%

36814-2

F25T8/TL835/ALTO

25

25

3500

36

30,000

36,000

2225

2115

85

95%

36825-8

F25T8/TL841/ALTO

25

25

4100

36

30,000

36,000

2225

2115

85

95%

14124-2

F25T8/TL850/ALTO

25

25

5000

36

30,000

36,000

2150

2040

82

95%

36826-6

F25T8/TL730/ALTO

25

25

3000

36

30,000

36,000

2125

2020

78

95%

36828-2

F25T8/TL735/ALTO

25

25

3500

36

30,000

36,000

2125

2020

78

95%

36829-0

F25T8/TL741/ALTO

25

25

4100

36

30,000

36,000

2125

2020

78

95%

24667-8

F32T8/TL830/ALTO

32

25

3000

48

30,000

36,000

2950

2800

85

95%

24670-2

F32T8/TL835/ALTO

32

25

3500

48

30,000

36,000

2950

2800

85

95%

24671-0

F32T8/TL841/ALTO

32

25

4100

48

30,000

36,000

2950

2800

85

95%

27229-4

F32T8/TL850/ALTO

32

25

5000

48

30,000

36,000

2850

2700

82

95%

27252-6

F32T8/TL730 ALTO

32

25

3000

48

30,000

36,000

2800

2660

78

95%

27249-2

F32T8/TL735/ALTO

32

25

3500

48

30,000

36,000

2800

2660

78

95%

27248-4

F32T8/TL741/ALTO

32

25

4100

48

30,000

36,000

2800

2660

78

95%

38351-3

F32T8/TL741/ALTO

32

10

4100

48

30,000

36,000

2800

2660

78

95%

27268-2

F32T8/TL750/ALTO

32

25

5000

48

30,000

36,000

2700

2565

78

95%

1)Average life under engineering data with lamps turned off and restarted once every 12 operating hours.

2)Approximate initial lumens.The lamp lumen output is based upon lamp performance after 100 hours of operating life, when the output is measured during operation on a reference ballast under standard laboratory conditions. For expected lamp lumen output, commercial ballast manufacturers can advise the appropriate ballast factor for each of their ballasts when they are informed of the designated lamp.The ballast factor is a multiplier applied to the designated lamp lumen output.

3)Design lumens are the approximate lamp lumen output at 40% of the lamp’s rated average life.This output is based upon measurements obtained during lamp operation on a reference ballast under standard laboratory conditions.

* It’s anticipated that lamp will be available Quarter 1, 2008.

E Lamp meets US Federal Minimum Efficiency Standards.

This lamp is better for the environment because of its reduced mercury content. All Philips ALTOIIlamps give you end-of-life options which can simplify and reduce your lamp disposal costs depending on your state and local regulations.

95% Lumen Maintenance

Rated Average Life

Philips T8 Lamps

Philips T8 Lamps

Light Output (%)

Instant Start Ballast

Programmed Start Ballast

100%

BASED ON 3 HOURS PER START4

98%

 

 

 

 

 

 

 

 

 

 

 

24,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

96%

 

 

 

 

 

 

 

 

 

 

 

 

30,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

94%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BASED ON 12 HOURS PER START1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

92%

 

 

 

 

 

 

 

 

 

 

 

 

30,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90%

 

 

 

 

 

 

 

 

 

 

 

 

36,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

5,000

10,000

15,000

20,000

25,000

30,000

35,000

40,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lamp Operating Hours

 

 

0

10,000

20,000

30,000

40,000

50,000

 

 

 

 

 

 

 

 

 

Rated Average Life in Hours

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4)Average life under specified test conditions with lamps turned off and restarted no more frequently than once every 3 operating hours. Lamp life is appreciably longer if lamps are started less frequently.

Specifications are subject to change without notice. © 2007 Philips Lighting Company. All rights reserved. Printed in USA 06/07

P-5338-G

www. philips.com

Philips Lighting Company

Philips Lighting

200 Franklin Square Drive

281 Hillmount Road

P.O. Box 6800

Markham, Ontario

Somerset, NJ 08875-6800

Canada L6C 2S3

1-800-555-0050

1-800-555-0050

A Division of Philips Electronics North America Corporation

A Division of Philips Electronics Ltd.

Printed on chlorine free paper from Sappi Fine Paper mills, who are accredited with EMAS environmental certification. Sappi claims that the pulp used in the manufacture of Magno Dull paper is derived from environmentally certified forests.

Page 2
Image 2
Philips P-5338-G warranty Ordering, Electrical andTechnical Data, 95% Lumen Maintenance Rated Average Life