Philips Lighting Company

www.philips.com

Philips Lighting

200 Franklin Square Drive

 

281 Hillmount Road

P.O.Box 6800

 

Markham, Ontario

Somerset, NJ 08875-6800

 

Canada L6C 2S3

1-800-555-0050

 

1-800-555-0050

A Division of Philips Electronics North America Corporation

A Division of Philips Electronics Ltd.

Updated 6/07

TDS-135541

 

MasterColor® Ceramic Metal Halide 38 Watt R111 Reflector Spot Lamp with FadeBlock

Electrical Data (Subject to change without notice)

Lamp Watts (Nominal) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

Lamp Operating Voltage (rms) (Nominal)4. . . . . . . . . . . . . 88

Initial Lamp Voltage Range (rms)5. . . . . . . . . . . . . . . . . . . . . 80-100

Lamp Operating Current (Amps) (rms) (Nominal) . . . . . 0.53

Lamp Current Crest Factor (Maximum) . . . . . . . . . . . . . . 1.8

Warm-up Time to 80% of Output . . . . . . . . . . . . . . . . . . . 3 Minutes

Re-strike Time for Hot Lamp . . . . . . . . . . . . . . . . . . . . . . . . 4-8 Minutes

Ballast Type (Electronic Only) . . . . . . . . . . . . . . . . . . . . . . . . ANSI M130/O

Ballast Open Circuit Voltage (Minimum). . . . . . . . . . . . . . . 198

Pulse PeakVolts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3000 Min.,4000 Max.

Pulse Width @ 90% Peak . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Micro Second Minimum

Pulse Repetition Rate (Minimum)6 . . . . . . . . . . . . . . . . . . . . 1 per Half Cycle

Minimum Operating Temperature. . . . . . . . . . . . . . . . . . . . -30ºC (-22ºF)

1)Measured at 100 hrs. life. Approximate lumen values listed are for vertical operation of the lamp.

2)Approximate lumen output at 40% of lamp rated average life.

3)Rated average life is the life obtained, on the average, from large representative groups of lamps in laboratory tests under controlled conditions at 10 or more operating hours per start. It is based on survival of at least 50% of the lamps and allows for individual lamps or groups of lamps to vary considerably from the average.

4)Measured at rated lamp watts on a linear reactor. LPW does not include ballast losses.

5)Measured with the lamp operating at rated watts.

6)Option-Pulse Width @ 90% Peak, 1 micro second minimum with 2 pulses per half cycle.

Warnings, Cautions and Operating Instructions

R“WARNING: These lamps can cause serious skin burn and eye inflammation from short wave ultraviolet radiation if outer envelope of the lamp is broken or punctured. Do not use where people will remain for more than a few minutes unless

adequate shielding or other safety precautions are used. Certain lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available.” This lamp complies with FDA radiation performance standard 21 CFR subchapter J. (USA:21CFR 1040.30 Canada: SOR/DORS/80-381)

If the outer bulb is broken or punctured, turn off at once and replace the lamp to avoid possible injury from hazardous short wave ultraviolet radiation. Do not scratch the outer bulb or subject it to pressure as this could cause the outer bulb to crack or shatter. A partial vacuum in the outer bulb may cause glass to fly if the envelope is struck.

WARNING: The arc-tube of metal halide lamps are designed to operate under high pressure and at tempera tures up to 1000º C and can unexpectedly rupt ure due to internal or external factors such as a ballast failure or misapplicat ion. If the arc-tube ruptures for any reason, the outer bulb may break and pieces of extremely hot glass might be discharged into the surrounding environment. If such a rupture were to happen, THERE

IS A RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE. These lamps are designed to retain all the glass particles should an arc tube rupture occur.The following operating instructions are recommended to minimize these occurrences.

RELAMP FIXTURESATOR BEFORETHE END OF RATED LIFE.Allowing lamps to operate until they fail is not advised and may increase the possibility of inner arc tube rupture.

This lamp contains an arc tube with a filling gas containing less than 10 nCi of Kr-85 and is distributed by Philips Lighting Company, a division of Philips Electronics North America Corporation, Somerset, New Jersey,08875.

CAUTION: TO REDUCE THE RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE RESULTING FROM AN ARC-TUBE RUPTURE THE FOLLOWING LAMP OPERATING INSTRUCTIONS MUST BE FOLLOWED:

LAMP OPERATING INSTRUCTIONS:

1.RELAMP FIXTURES AT OR BEFORE THE END OF RATED LIFE. Allowing lamps to operate until they fail is not advised and may increase the possibility of inner arc tube rupture.

2.Before lamp installation/replacement, shut power off and allow lamp and fixture to cool to avoid electrical shock and potential burn hazards.

3.Use only auxiliary equipment meeting Philips and/or ANSI standards. Use within voltage limits recommended by ballast manufacturer.

A.Operate lamp only within specified limits of operation.

B.For total supply load refer to ballast manufacturers electrical data.

C.Operate 39W PAR-20 and PAR-30L lamps only on thermally

protected ballast.

D.OperateCDM-R111 lamponly on approvedthermally protected electronic ballast.

4.Periodically inspect the outer envelope. Replace any lamps that show scratches, cracks or damage.

5.If a lamp bulb support is used, be sure to insulate the support electrically to avoid possible decomposition of the bulb glass.

6.Protect lamp base, socket and wiring against moisture, corrosive atmospheres and excessive heat.

7.Time should be allowed for lamps to stabilize in color when turned on for the first time. This may require several hours of operation, with more than one start. Lamp color is also subject to change under conditions of excess vibration or shock, and color appearance may vary between individual lamps.

8.Lamps may require up to 10 minutes (4–8 minutes for CDM-R111) to re-light if there is a power interruption.

9.Take care in handling and disposing of lamps. If an arc tube is broken, avoid skin contact with any of the contents or fragments.

10.For proper installation and removal, lamp should be handled by the sides of the reflector and not by the aluminum front anti-glare cap.

Page 2
Image 2
Philips R111 manual Lamp Operating Instructions

R111 specifications

The Philips R111 is a versatile and efficient lighting solution designed primarily for commercial and residential use. This innovative lighting fixture features a range of attributes that make it an ideal choice for various applications, from retail spaces to office environments.

One of the standout features of the Philips R111 is its compact design, which allows for easy integration into different architectural styles. The fixture typically uses a GU10 base, making it compatible with a wide range of LED and halogen bulbs. This flexibility enables users to choose the most suitable lighting technology for their specific needs.

In terms of illumination performance, the Philips R111 is known for its high lumen output and superior color rendering capabilities. It offers a bright and uniform light distribution, enhancing visibility and ambiance in any space. The fixture supports adjustable beam angles, allowing users to direct light precisely where it's needed, making it an excellent choice for accent lighting or general illumination.

Energy efficiency is another hallmark of the Philips R111. The fixture is engineered to minimize energy consumption while providing exceptional lighting quality. When paired with LED bulbs, it achieves remarkable energy savings compared to traditional halogen options, contributing to lower electricity bills and a reduced carbon footprint.

The technology behind the Philips R111 includes advanced thermal management systems, which ensure that the fixture remains cool during operation. This prolongs the lifespan of the light source and reduces maintenance needs, making it a cost-effective solution for any lighting project. Additionally, many models come with dimming capabilities, providing further control over light intensity and mood.

Durability is also a significant characteristic of the Philips R111. Built with quality materials, the fixture is designed to withstand the rigors of daily use in demanding environments. This reliability ensures that users can count on the R111 for long-term performance.

In summary, the Philips R111 is a highly adaptable lighting solution that combines cutting-edge technologies with practical features. Its outstanding performance, energy efficiency, and design versatility make it a top choice for those looking to enhance their spaces with quality lighting. Whether for a cozy home setting or a bustling commercial space, the Philips R111 is sure to meet and exceed expectations.