Philips Lighting Company | www.philips.com | Philips Lighting |
200 Franklin Square Drive |
| 281 Hillmount Road |
P.O. Box 6800 |
| Markham, Ontario |
Somerset, NJ |
| Canada L6C 2S3 |
| ||
A Division of Philips Electronics North America Corporation | A Division of Philips Electronics Ltd. | |
Printed in the USA 12/05 |
|
SILHOUETTE™ T5 Fluorescent Lamps featuring ALTO® Lamp Technology
Electrical,Technical and Ordering Data (Subject to change without notice)
|
|
|
|
|
|
|
|
| Average | Rated |
|
|
|
|
|
|
|
|
| Std. | Color | Color | Nominal | Average | Approx. |
|
|
| Product |
| Nominal |
|
| Pkg. | Temp. | Rendering | Length | Life | Initial | Design |
|
| Number | Description | Watts | Bulb | Base | Qty. | (Kelvin) | (CRI) | (in) | (hrs)1 | Lumens2,3 | Lumens4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| F14T5/830/ALTO | 14 | T5 | Min. Bipin | 40 | 3000K | 85 | 22 | 20,000 | 1350 | 1275 |
| |
| F14T5/835/ALTO | 14 | T5 | Min. Bipin | 40 | 3500K | 85 | 22 | 20,000 | 1350 | 1275 |
| |
| F14T5/841/ALTO | 14 | T5 | Min. Bipin | 40 | 4100K | 85 | 22 | 20,000 | 1350 | 1275 |
| |
| F21T5/830/ALTO | 21 | T5 | Min. Bipin | 40 | 3000K | 85 | 34 | 20,000 | 2100 | 2000 |
| |
| F21T5/835/ALTO | 21 | T5 | Min. Bipin | 40 | 3500K | 85 | 34 | 20,000 | 2100 | 2000 |
| |
| F21T5/841/ALTO | 21 | T5 | Min. Bipin | 40 | 4100K | 85 | 34 | 20,000 | 2100 | 2000 |
| |
| F28T5/830/ALTO | 28 | T5 | Min. Bipin | 40 | 3000K | 85 | 46 | 20,000 | 2900 | 2750 |
| |
| F28T5/835/ALTO | 28 | T5 | Min. Bipin | 40 | 3500K | 85 | 46 | 20,000 | 2900 | 2750 |
| |
| F28T5/841/ALTO | 28 | T5 | Min. Bipin | 40 | 4100K | 85 | 46 | 20,000 | 2900 | 2750 |
| |
| F35T5/830 | 35 | T5 | Min. Bipin | 40 | 3000K | 85 | 58 | 20,000 | 3650 | 3450 |
| |
| F35T5/835 | 35 | T5 | Min. Bipin | 40 | 3500K | 85 | 58 | 20,000 | 3650 | 3450 |
| |
| F35T5/841 | 35 | T5 | Min. Bipin | 40 | 4100K | 85 | 58 | 20,000 | 3650 | 3450 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1)Average life under specified test conditions with lamps turned off and restarted no more frequently than once every 3 operating hours. Lamp life is appreciably longer if lamps are started less frequently,
2)Approximate initial lumens.The lamp lumen output is based upon lamp performance after 100 hours of operating life, when the output is measured during operation on a reference ballast under standard laboratory conditions.
3)For expected lamp lumen output, commercial ballast manufacturers can advise the appropriate ballast factor for each of their ballasts when they are informed of the designated lamp. The ballast factor is a multiplier applied to the designated lamp lumen output.
4)Design lumens are the approximate lamp lumen output at 40% of the lamp’s rated average life.This output is based upon measurements obtained during lamp operation on a reference ballast under standard laboratory conditions.
Spectral Power Distribution
Relative Energy
Spectral Power Distribution |
|
|
| Spectral Power Distribution |
|
|
| Spectral Power Distribution |
|
| ||||||||||||
100 |
|
|
|
|
|
|
| 100 |
|
|
|
|
|
|
| 100 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
80 |
|
|
|
|
|
|
| 80 |
|
|
|
|
|
|
| 80 |
|
|
|
|
|
|
|
|
|
|
|
| Energy |
|
|
|
|
|
|
| Energy |
|
|
|
|
|
|
| |
60 |
|
|
|
|
|
| 60 |
|
|
|
|
|
| 60 |
|
|
|
|
|
| ||
|
|
|
|
|
| Relative |
|
|
|
|
|
|
| Relative |
|
|
|
|
|
|
| |
40 |
|
|
|
|
|
| 40 |
|
|
|
|
|
| 40 |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
20 |
|
|
|
|
|
|
| 20 |
|
|
|
|
|
|
| 20 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
0 |
|
|
|
|
|
|
| 0 |
|
|
|
|
|
|
| 0 |
|
|
|
|
|
|
|
|
|
|
|
|
| 400 | 450 | 500 | 550 | 600 | 650 | 700 |
| 400 | 450 | 500 | 550 | 600 | 650 | 700 | |
400 | 450 | 500 | 550 | 600 | 650 | 700 |
|
| ||||||||||||||
|
| Wavelength (Nanometers) |
|
|
|
|
| Wavelength (Nanometers) |
|
|
|
|
| Wavelength (Nanometers) |
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Lamp Dimensions
|
|
|
|
| A |
| B |
| B |
| C | |
C |
|
| Lamp | MAX. |
| MIN. | MAX. | MAX. | ||||
MAX. O.D. |
| Type | inches | mm | inches | mm | inches | mm | inches | mm | ||
B | 17.0 mm | |||||||||||
.67 in. | ||||||||||||
A |
|
|
|
|
|
|
|
| ||||
| 21.61 | 549.0 | 21.80 | 553.7 | 21.89 | 556.1 | 22.17 | 563.2 | ||||
|
|
| F14T5 | |||||||||
|
|
| F21T5 | 33.42 | 849.0 | 33.61 | 853.7 | 33.70 | 856.1 | 33.98 | 863.2 | |
|
|
| F28T5 | 45.24 | 1149.0 | 45.42 | 1153.7 | 45.52 | 1156.1 | 45.80 | 1163.2 | |
|
|
| F35T5 | 57.05 | 1449.0 | 57.23 | 1453.7 | 57.33 | 1456.1 | 57.61 | 1463.2 | |
|
|
| Silhouette™ T5 Lumens vs. Ambient Temperature |
| Energy Lumen Maintenance |
|
| |||||
|
|
|
|
|
|
| T5/HO — 2004 |
|
|
|
| 110 |
|
|
|
|
|
|
|
|
|
|
|
|
| 102 |
|
|
|
|
|
|
| 100 |
|
|
|
|
|
|
|
|
|
|
|
|
| 100 |
|
|
|
|
|
|
| 90 |
|
|
|
|
|
|
|
|
|
|
|
| (%) |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| 80 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
(%)tutpuOne |
|
|
|
|
|
|
|
|
|
|
|
| utpuOhtgLit | 98 |
|
|
|
|
|
| |
| 70 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| T5 |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| 60 |
|
|
|
|
|
|
|
|
|
|
| T8 |
| 96 |
|
|
|
|
|
|
umL | 50 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
40 |
|
|
|
|
|
|
|
|
|
|
|
|
| 94 |
|
|
|
|
|
| |
| 30 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 20 |
|
|
|
|
|
|
|
|
|
|
|
|
| 92 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 10 |
|
|
|
|
|
|
|
|
|
|
|
|
| 90 |
|
|
|
|
|
|
| 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| 20 | 25 |
|
| 40 |
| 50 |
|
|
|
| 0 | 5000 | 10000 | 15000 | 20000 | 25000 | 30000 | |
| 5 | 10 | 15 | 30 | 35 | 45 | 55 |
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
| ||||||||||||
|
|
|
| Ambient Temperature (°C) |
|
|
|
|
|
|
|
|
|
| Lamp Operating Hours |
|
|
|