108
RS-232C Adjustment Mode
3) <GET> (GET STATUS) — The status of various settings is transmitted in the following formats:
Output items [Example of output] = Setting status when the signals to the
left are issued
(1) STX (02H)
(2) Version of microcomputer software (5 bytes) [5435A] = Version A
(3) Input function status (3 bytes) [IN1] = INPUT 1
(4) Color-mode setting status (3 bytes) [CM1] = COLOUR MODE 1
(5) Full auto zoom setting status (3 bytes) [AZN] = Full Auto Zoom: OFF
(6) Screen-size setting status (3 bytes) [SM2] = Screen-Size Setting: FULL
(7) Auto power off setting status (3 bytes) [APN] = Auto Power Off: OFF
(8) 3-dimensional Y/C Separator Setting Status
(3 Bytes) [ YCM] = 3D Y/C MODE: MOTION
(For U.S. models and Taiwanese models)
(9) COLOUR SYS Setting Status (3 Bytes) [TVA] = COLOUR SYS: AUTO
(For EURO models only)
(10)Status of connected equipment settings and input signal format settings
(3 bytes) [BBY] = INPUT SETTING: VIDEO; SIGNAL: RGB
(11)Clamp position setting status (3 bytes) [CL1] = CLAMP: MODE 1
(12)ABL setting status (3 bytes) [ABY] = ABL: ON
(13)MP mode setting status (3 bytes) [MPY] = MP: ON
(14)KEY LOCK/UNLOCK (3 bytes) [KLN] = UNLOCK (available either from the remote
or the operating panel of the main unit)
(15)OSD display setting status (3 bytes) [DIN] = OSD not displayed
(16)Mirror mode setting status (3 bytes) [MMZ] = MIRROR MODE: XY
(17)Dummy data (3 bytes)
(18)STD-RGB setting status (3 bytes) [NRY] = STD-RGB: ON
(19)ETX (03H)
NOTES:• Refer to P.74 to P.94 and P.113 for the setting for each item.
When the input function is INPUT 1, the dummy data is issued for:
(10)Status of connected equipment settings and input signal format settings
(11)Clamp position setting status
(12)ABL setting status
(13)MP mode setting status
When the input function is INPUT 2, or INPUT 3 or 4 and in the VIDEO setting, the dummy data is issued for:
(8) 3-dimensional Y/C separator setting status
(11)Clamp position setting status
(12)ABL setting status
(13)MP mode setting status
When the input function is INPUT 3 or 4 and in the PC setting, the dummy data is issued for:
(8) 3-dimensional Y/C separator setting status