Sequence | Data Content | Size | Remarks |
1 | STX | 1 Byte | 02hex |
|
|
|
|
2 | Command | 3 Byte | QSU (fixed) |
|
|
|
|
3 | Main volume | 3 Byte | 000 to 042 |
|
|
|
|
4 | Audio mute status | 1 Byte | 0: OFF 1: ON |
|
|
|
|
5 | INPUT1 sub volume | 3 Byte | 000 to 020 |
|
|
|
|
6 | INPUT2 sub volume | 3 Byte | 000 to 020 |
|
|
|
|
7 | INPUT3 sub volume | 3 Byte | 000 to 020 |
|
|
|
|
8 | INPUT4 sub volume | 3 Byte | 000 to 020 |
|
|
|
|
9 | INPUT5 sub volume | 3 Byte | 000 to 020 |
|
|
|
|
10 | Check sum | 2 Byte |
|
|
|
|
|
11 | ETX | 1 Byte | 03hex |
Sequence | Data Content | Size |
|
| Remarks |
| |
1 | STX | 1 Byte | 02hex |
|
|
|
|
|
|
|
|
|
|
|
|
2 | Command | 3 Byte | QCI (fixed) |
|
|
|
|
|
|
|
|
| |||
3 | Time information | 2 Byte | Hour (24 hour system) 00 to 23 Note 1) |
| |||
|
|
|
|
|
|
| |
|
| 2 Byte | Minute 00 to 59 | Note 1) |
|
| |
|
|
|
|
|
|
| |
|
| 2 Byte | Second 00 to 59 | Note 1) |
|
| |
|
|
|
|
|
|
|
|
4 | Dummy data | 8 Byte |
|
|
|
|
|
|
|
|
|
|
|
| |
5 | Day of week | 1 Byte | 1: Sunday | 2: Monday | 3: Tuesday | 4: Wednesday | |
|
|
| 5: Thursday | 6: Friday | 7: Saturday | Note 1) | |
|
|
|
|
|
|
|
|
6 | Check sum | 2 Byte |
|
|
|
|
|
|
|
|
|
|
|
|
|
7 | ETX | 1 Byte | 03hex |
|
|
|
|
Note 1) During standby and when this command was initially set, the value at the time that power was finally shut off is transmitted.
9) <QAP> Obtaining machine nameSequence | Data Content | Size | Remarks |
1 | STX | 1 Byte | 02hex |
|
|
|
|
2 | Command | 3 Byte | QAP (fixed) |
|
|
|
|
3 | Machine name information | 18 Byte | 42 inch: |
|
|
| A (North America model): |
|
|
| G |
|
|
|
|
|
|
| 50 inch: |
|
|
| J (Japan model): |
|
|
| A (North America model): |
|
|
| G |
|
|
| GS |
|
|
|
|
4 | Check sum | 2 Byte |
|
|
|
|
|
5 | ETX | 1 Byte | 03hex |
|
|
|
|
20