Model SSH55, SSH55T and SSH75 Solstice Supreme Gas Fryer
Gas Fryer
3/4 INCH GAS CONNECTION (CE 3/4 INCH BSP ADAPTOR
G ADDS 1 1/2 [3.8] TO
CONNECTION)
6 FOOT (183 CM) POWER
PCORD (NEMA
A
P
SSH55/55T SSH75
A48 11/32 [122.8] 52 11/32 [132.9]
B15 5/8 [39.7] 19 5/8 [49.8]
C | 4 1/4 [10.8] | 6 1/4 [15.9] |
and SSH75 Solstice Supreme
38 11/32 [97.4] 34 15/32 [87.5]
B | IN [CM] | INTEGRAL FLUE DEFLECTOR | |
OPTIONAL BASKET LIFT | |||
| |||
| OPTIONAL |
| |
| COMPUTER |
| |
| SOLID STATE |
| |
| THERMOSTAT |
| |
| 34 [86.4] |
| |
| NOM. |
|
11/16
[1.7]
54 13/32
[138.2]
NOM.
P
46 1/8
[117.1]
SSH55T
G |
G
NOM.
Model SSH55,
12 13/16 | |
[32.5] | 9 [22.9] |
NOM. | NOM. |
C | 21 7/8 [55.6] |
|
101/2
[26.7]
NOM.
1 13/32 [3.6]
4 13/32 [11.2]
INDIVIDUAL FRYER SPECIFICATIONS
Model | Frying Area | Cook Depth | Oil Capacity | Gas Input Rate / Hr | |
SSH55 | 14 x 14 in (35.6 x35.6cm) | 40 - 50 Lbs (18 - 23 kg) | 80,000 | BTUs (23 kW) (84 MJ) | |
SSH55T per side | 7 x 14 in (35.6 x35.6cm) | 20 - 25 Lbs (9 | 40,000 | BTUs (18 kW) (42 MJ) | |
SSH75 | 18 x 18 in (45.7 x 45.7 cm) | 75 Lbs (34 kg) | 105,000 | BTUs (31 kW) (110 MJ) |
FRYER SHIPPING INFORMATION (Approximate)
Model | Shipping Weight | Shipping Weight w B/L | Shipping Crate Size H x W x L | Shipping Cube | ||
SSH55 | 208 | Lbs (95 kg) | 258 Lbs (117 kg) | 58 x 22 x 44 in | (147.3 x 55.8 x 111.7 cm) | 32.5 ft3. (0.9m3 ) |
SSH55T | 230 | Lbs (104 kg) | 280 Lbs (127 kg) | 58 x 22 x 44 in | (147.3 x 55.8 x 111.7 cm) | 32.5 ft3. (0.9m3 ) |
SSH75 | 226 | Lbs (103 kg) | 276 Lbs (125 kg) | 58 x 22 x 44 in | (147.3 x 55.8 x 111.7 cm) | 32.5 ft3. (0.9m3 ) |
INSTALLATION INFORMATION
| GAS SYSTEM REQUIREMENTS |
|
|
| ELECTRIC SYSTEM REQUIREMENTS (50/60 hz) | |||||||
Gas Type | Store Supply Pressure * | Burner Manifold Pressure |
| Amps | # of Cord | 115V | 208 / | |||||
Natural | 7 - 10" w.c.(17.4 mbars/ 1.7 kPa) | 4" w.c. (10 mbars / 1 kPa) |
| Fryer | 1 | 0.7 | 0.4 | |||||
Propane | 11 - 13" w.c.(27.4 mbars/ 2.7 kPa) | 10" w.c. (25mbars/2.4 kPa) |
| |||||||||
|
|
|
|
|
| |||||||
* Check plumbing / gas codes for proper gas supply line sizing to sustain burner pressure when all gas appliances are full on. | ||||||||||||
|
|
| CLEARANCES (Do Not Curb Mount) |
|
|
| ||||||
Front min. | Floor min. | Combustible material |
| Fryer Flue Area | ||||||||
30" | 6" | Sides min. | Rear min. | Sides min. | Rear min. | Do not block / restrict flue gases from flowing into hood | ||||||
(76.2 cm) | (15.25 cm) | 6" (15.2cm) | 6" (15.2cm) | 0" |
| 0" |
| or install vent hood drains over the flue. | ||||
|
|
| SHORT | FORM SPECIFICATION |
|
|
|
|
Provide Pitco Model (SSH55,55T,75) tube fired high efficiency gas floor fryer with EnergyStar TM**rating. Fryer shall be
Pitco Frialator, Inc • P.O. Box 501, Concord, NH
We reserve the right to change specifications without notice and without incurring any obligation for equipment previously or subsequently sold.