Aug/07 MN2036400000
11
Rebuilding a Failed Mirror Set When a failure to one member occurs, you will be notified either by the
RAID BIOS during boot or by the SATARAID GUI while in
Windows. The steps below will guide you in rebuilding a failed mirror
set.
1. Replace the failed drive with one of equal or greater capacity, then
start the computer.
2. During boot press Ctrl+S or F4 to enter the RAID BIOS.
3. Select Rebuild Mirrored Set then press Enter.
4. Select the desired set and then press Enter.
5. Select online rebuild if you wish to rebuild the mirror in the
background when you boot into Windows. Select offline rebuild
if you wish to rebuild the mirror now. This might take some time.
6. When asked Are You Sure(Y/N)?, press Y to confirm.
7. The set will be rebuilt.
1. As the BIOS boots press Ctrl+S or F4 when prompted to enter
the RAID BIOS.
2. Select Delete RAID Set, then press Enter.
3. Select the RAID set then press Enter.