UK

Error Messages

The following table details the cause and subsequent response of the appliance to errors.

Error Message

Cause
Appliance Response

Action

(flashing)

 

 

 

 

 

 

 

 

The inner temperature exceeds

Display flashes

Check Troubleshooting Guide

HtA

If problem persists call POLAR agent or

the set maximum temperature

Alternating error message and current temperature

 

qualified Technician

 

 

 

 

 

 

 

 

The inner temperature exceeds

Display flashes

Check Troubleshooting Guide

LtA

If problem persists call POLAR agent or

the set minimum temperature

Alternating error message and current temperature

 

qualified Technician

 

 

 

 

 

 

 

PF1

Short circuit or interruption of

Display flashes

Compressor operates as specified by

the thermostat probe input line

parameter ‘=23

 

 

 

 

 

 

PF2

Short circuit or interruption of

Display flashes

Defrost as specified by parameters d8 and d9

the evaporator probe input line

 

 

 

 

 

 

 

HLA

Inner temperature greater than

Display flashes

Call POLAR agent or qualified Technician

90°C

Alternating error message and current temperature

 

 

 

 

 

 

LLA

Inner temperature lower than

Display flashes

Call POLAR agent or qualified Technician

-45°C

Alternating error message and current temperature

 

 

 

 

 

 

The alarm message will end when the alarm trigger is no longer present, except PF1 and PF2 that require the appliance to be turned Off, then On again.

Technical Specifications

Model
Voltage
Power
Current
Temperature
Capacity
Refrigerant
Dimensions
Weight

Range

(litres)

H x W x D (mm)

(Kg)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G596

230V 50Hz

340W

1.5A

-2°C to 10°C

282

R134a 240g

850 x 1360 x 700

98

 

 

 

 

 

 

 

 

 

G597

230V 50Hz

340W

1.5A

-2°C to 10°C

417

R134a 240g

850 x 1795 x 700

134

 

 

 

 

 

 

 

 

 

G598

230V 50Hz

450W

2A

-2°C to 10°C

563

R134a 250g

850 x 2230 x 700

153

 

 

 

 

 

 

 

 

 

G599

230V 50Hz

1000W

4.35A

-10°C to -20°C

282

R404 300g

850 x 1360 x 700

103

 

 

 

 

 

 

 

 

 

G600

230V 50Hz

1000W

4.35A

-10°C to -20°C

417

R404 260g

850 x 1795 x 700

136

 

 

 

 

 

 

 

 

 

G601

230V 50Hz

1000W

4.35A

-10°C to -20°C

563

R404 320g

850 x 2230 x 700

155

 

 

 

 

 

 

 

 

 

G621

230V 50Hz

340W

1.5A

-2°C to 10°C

417

R134a 240g

900 x 900 x 700

140

 

 

 

 

 

 

 

 

 

G622

230V 50Hz

340W

1.5A

-2°C to 10°C

368

R134a 250g

850 x 1365 x 700

107

 

 

 

 

 

 

 

 

 

U636

230V 50Hz

250W

1A

-2°C to 10°C

240

R134a 165g

850 x 900 x 700

70

 

 

 

 

 

 

 

 

 

U637

230V 50Hz

250W

1A

-2°C to 10°C

240

R134a 165g

850 x 900 x 700

71

 

 

 

 

 

 

 

 

 

U638

230V 50Hz

250W

1A

-2°C to 10°C

240

R134a 165g

850 x 900 x 700

72

 

 

 

 

 

 

 

 

 

Electrical Wiring

POLAR appliances are supplied with a 3 pin, moulded, BS1363 plug and lead, with a 13 amp fuse as standard.

The plug is to be connected to a suitable mains socket.

POLAR appliances are wired as follows:

Live wire (coloured brown) to terminal marked L

Neutral wire (coloured blue) to terminal marked N

Earth wire (coloured green/yellow) to terminal marked E

All POLAR appliances must be earthed, using a dedicated earthing circuit. If in doubt consult a qualified electrician.

Electrical isolation points must be kept clear of any obstructions. In the event of any emergency disconnection being required they must be readily accessible.

Compliance

POLAR parts have undergone strict product testing in order to comply with regulatory standards and specifications set by international, independent, and federal authorities.

POLAR products have been approved to carry the following symbol:

4