UK
Error Messages
The following table details the cause and subsequent response of the appliance to errors.
Error Message | Cause | Appliance Response | Action | |
(flashing) | ||||
|
|
| ||
|
|
|
| |
| The inner temperature exceeds | Display flashes | Check Troubleshooting Guide | |
HtA | If problem persists call POLAR agent or | |||
the set maximum temperature | Alternating error message and current temperature | |||
| qualified Technician | |||
|
|
| ||
|
|
|
| |
| The inner temperature exceeds | Display flashes | Check Troubleshooting Guide | |
LtA | If problem persists call POLAR agent or | |||
the set minimum temperature | Alternating error message and current temperature | |||
| qualified Technician | |||
|
|
| ||
|
|
|
| |
PF1 | Short circuit or interruption of | Display flashes | Compressor operates as specified by | |
the thermostat probe input line | parameter ‘=23’ | |||
|
| |||
|
|
|
| |
PF2 | Short circuit or interruption of | Display flashes | Defrost as specified by parameters d8 and d9 | |
the evaporator probe input line | ||||
|
|
| ||
|
|
|
| |
HLA | Inner temperature greater than | Display flashes | Call POLAR agent or qualified Technician | |
90°C | Alternating error message and current temperature | |||
|
| |||
|
|
|
| |
LLA | Inner temperature lower than | Display flashes | Call POLAR agent or qualified Technician | |
Alternating error message and current temperature | ||||
|
| |||
|
|
|
|
The alarm message will end when the alarm trigger is no longer present, except PF1 and PF2 that require the appliance to be turned Off, then On again.
Technical Specifications
Model | Voltage | Power | Current | Temperature | Capacity | Refrigerant | Dimensions | Weight | |
Range | (litres) | H x W x D (mm) | (Kg) | ||||||
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
| |
G596 | 230V 50Hz | 340W | 1.5A | 282 | R134a 240g | 850 x 1360 x 700 | 98 | ||
|
|
|
|
|
|
|
|
| |
G597 | 230V 50Hz | 340W | 1.5A | 417 | R134a 240g | 850 x 1795 x 700 | 134 | ||
|
|
|
|
|
|
|
|
| |
G598 | 230V 50Hz | 450W | 2A | 563 | R134a 250g | 850 x 2230 x 700 | 153 | ||
|
|
|
|
|
|
|
|
| |
G599 | 230V 50Hz | 1000W | 4.35A | 282 | R404 300g | 850 x 1360 x 700 | 103 | ||
|
|
|
|
|
|
|
|
| |
G600 | 230V 50Hz | 1000W | 4.35A | 417 | R404 260g | 850 x 1795 x 700 | 136 | ||
|
|
|
|
|
|
|
|
| |
G601 | 230V 50Hz | 1000W | 4.35A | 563 | R404 320g | 850 x 2230 x 700 | 155 | ||
|
|
|
|
|
|
|
|
| |
G621 | 230V 50Hz | 340W | 1.5A | 417 | R134a 240g | 900 x 900 x 700 | 140 | ||
|
|
|
|
|
|
|
|
| |
G622 | 230V 50Hz | 340W | 1.5A | 368 | R134a 250g | 850 x 1365 x 700 | 107 | ||
|
|
|
|
|
|
|
|
| |
U636 | 230V 50Hz | 250W | 1A | 240 | R134a 165g | 850 x 900 x 700 | 70 | ||
|
|
|
|
|
|
|
|
| |
U637 | 230V 50Hz | 250W | 1A | 240 | R134a 165g | 850 x 900 x 700 | 71 | ||
|
|
|
|
|
|
|
|
| |
U638 | 230V 50Hz | 250W | 1A | 240 | R134a 165g | 850 x 900 x 700 | 72 | ||
|
|
|
|
|
|
|
|
|
Electrical Wiring
POLAR appliances are supplied with a 3 pin, moulded, BS1363 plug and lead, with a 13 amp fuse as standard.
The plug is to be connected to a suitable mains socket.
POLAR appliances are wired as follows:
•Live wire (coloured brown) to terminal marked L
•Neutral wire (coloured blue) to terminal marked N
•Earth wire (coloured green/yellow) to terminal marked E
All POLAR appliances must be earthed, using a dedicated earthing circuit. If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency disconnection being required they must be readily accessible.
Compliance
POLAR parts have undergone strict product testing in order to comply with regulatory standards and specifications set by international, independent, and federal authorities.
POLAR products have been approved to carry the following symbol:
4