BUILDING YOUR SYSTEM WITH MULTIPLE VOR-

Operating as One Automixer with Multiple Vortexes

Example: Room Combining

To set the Vortex to operate as one automixer across several Vortexes, set the BUS MIXER parameter on all Vortexes to the same automixer group.

Let’s take a room combining setup as an example. You have 3 rooms, each with 8 microphones, therefore needing 3 Vortexes. For the purposes of this example, the 3 rooms can operate as 3 separate rooms, 2 rooms with 12 mics each, or one large room.

When the system is split into 3 Rooms, the BUS MIXER option should have the fol- lowing settings:

ROOM

VORTEX ID

AUTOMIXER

BUS MIXER

MICS

 

 

 

 

 

 

 

 

 

 

1

00

AM1

0

1-8

 

 

 

 

 

2

01

AM1

0

1-8

 

 

 

 

 

3

02

AM1

0

1-8

 

 

 

 

 

Table 1: BUS MIXER settings for 3 separate rooms each with 8 microphones operating independently

When split into 2 Rooms:

ROOM

VORTEX ID

AUTOMIXER

BUS MIXER

MICS

 

 

 

 

 

 

 

 

 

 

1

00

AM1

1

1-8

 

 

 

 

 

2

01

AM1

1

1-4

 

 

 

 

 

2

01

AM2

2

5-8

 

 

 

 

 

3

02

AM2

2

1-8

 

 

 

 

 

Table 2: BUS MIXER settings for 2 rooms with 12 microphones each

And finally, all combined into one room:

ROOM

VORTEX ID

AUTOMIXER

BUS MIXER

MICS

 

 

 

 

 

 

 

 

 

 

1

00

AM1

3

1-8

 

 

 

 

 

2

01

AM1

3

1-8

 

 

 

 

 

3

02

AM1

3

1-8

 

 

 

 

 

Table 3: BUS MIXER settings for one room with 24 microphones

The various room setups can be saved in the user defined presets or can be changed with macros.

Vortex® Applications and Presets Guide

6

Technical Support: (800) 932-2774

Page 8
Image 8
Polycom EF2280 manual AM1