Porter-Cable CFFN251T Maintenance, How to Start, Customer Responsibilities, To Check Safety Valve

Models: CFFN251T

1 20
Download 20 pages 41.39 Kb
Page 13
Image 13

Risk of Bursting. Too much air

pressure causes a hazardous risk of bursting. Check the manufacturer’s maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating.

How to Start:

1.Set the On/Off switch to ON (I) and allow tank pressure to build. Motor will stop when tank pressure reaches "cut-out" pressure.

2.Pull the regulator knob out and turn clockwise to increase pressure. When the desired pressure is reached push knob in to lock in place.

The compressor is ready for use.

MAINTENANCE

Customer Responsibilities

 

Before

Daily

 

each

or after

 

each

 

use

 

use

 

 

Check Safety Valve

 

 

 

 

Drain Tank

 

Unit cycles automatically when

power is on. When performing maintenance, you may be exposed to voltage sources, compressed air, or moving parts. Personal injuries can occur. Before performing any maintenance or repair, disconnect power source from the compressor and bleed off all air pressure.

NOTE: See "Operation" section for the location of controls.

To Check Safety Valve

If the safety valve does not work

properly, over-pressurization may occur, causing air tank rupture or an explosion.

1.Before starting compressor, pull the ring on the safety valve to make sure that the safety valve operates freely. If the valve

is stuck or does not operate smoothly, it must be replaced with the same type of valve.

13 - ENG

A11894

Page 13
Image 13
Porter-Cable CFFN251T instruction manual Maintenance, How to Start, Customer Responsibilities, To Check Safety Valve