Porter-Cable D29851-038-0 Assembly, Remove Generator From Carton, Other Loose Parts

Models: D29851-038-0

1 22
Download 22 pages 15.82 Kb
Page 9
Image 9
ASSEMBLY

ASSEMBLY

Read this manual. Do not attempt to operate equipment until you have read this Manual for Safety, Operation, and

Maintenance Instructions.

NOTE: This manual is a general manual. Information in this manual may or may not pertain to your model. Please read carefully.

NOTE: Left and right describes the location of a part with the operator facing the outlet panel.

REMOVE GENERATOR FROM CARTON

Open carton from top.

Cut carton along dotted lines.

Remove all carton inserts.

Remove generator through opening in carton.

• Remove shipping block(s) from under the gen head. Unscrew bolt(s) and remove the shipping block(s). It is very important that this is removed before starting your generator.

OTHER LOOSE PARTS

1.Oil is supplied, see engine operators manual for correct procedure to add oil and fuel to engine.

2.The locking plugs maybe used when needed or required.

The locking plugs are to be installed and/or used in accordance with appropriate local electrical code

regulations. Refer to instructions enclosed with each plug for proper installation.

3.12V DC cables to be used with the 12V DC outlets. See Operation section. IMPORTANT: Before any attempt to start your generator be sure to check engine oil (See Engine Operator's manual)

GROUNDING THE GENERATOR

A grounding lug is supplied with the generator for

Grounding Lug

use when required by local electrical ordinances.

 

Refer to article 250 of the National Electrical Code

 

to clarify any needed grounding information. Your

 

local electric company or a certified electrician

 

should be able to help you with this information.

 

9- ENG

D29851

Page 9
Image 9
Porter-Cable D29851-038-0 Assembly, Remove Generator From Carton, Other Loose Parts, Grounding The Generator