OPERATION

OPERATION

KNOW YOUR GENERATOR

Read this General Manual and Safety Rules before operation of your Generator. Compare the illustration in your parts manual with your generator to familiarize yourself with the location of various controls and adjustments. Save all manuals for future references.

GENERATOR CAPACITY

IMPORTANT: Exceeding the rated capacity of your generator can result in serious damage to your generator and connected electrical devices. See the Wattage Calculation section in this manual to assist you in determining the appliances and tools that can be run with the wattage capacity of your generator.

CIRCUIT BREAKERS

Each receptacle has a circuit breaker to protect the generator from overloading. If the circuit breaker trips, unplug all electrical loads from the generator. Let the circuit breaker cool down. Push circuit breaker button to reset.

BEFORE START UP

This generator has been shipped from the factory without oil in the crankcase. Operating the unit without oil can damage the engine.

Always check engine oil level before every start. Running engine low of oil or out of oil could result in serious damage to the engine.

Follow the steps listed below before starting generator:

1.Check engine oil. Refer to the Engine Operator's Manual for

correct grade and quantity of oil.

2.Check fuel level, fill as required. Make sure generator is turned off and has been allowed time to cool down. Use

clean, fresh, regular unleaded gasoline with a minimum of 87 octane. Do not mix oil with gasoline.

Never fill fuel tank completely. Fill tank to 1/2" below the bottom of the filler neck to

provide space for fuel expansion. Wipe any fuel spillage from engine and equipment before starting engine.

Never fill fuel tank indoors. Never fill fuel tank when engine is running or hot. Do not smoke when filling fuel tank.

Never run engine indoors or in enclosed, poor ventilated areas, en- gine exhaust contains carbon monoxide, an odorless and deadly gas.

3.Make sure generator is grounded in accordance with local requirements.

4.All electrical loads MUST be disconnected.

Engine speed has been factory set to provide safe operation. Tampering with the engine speed adjustment could result in over-

heating of attachments and could cause a fire. Never attempt to “speed-up” the en- gine to obtain more performance. Both the output voltage and frequency will be thrown out of standard by this practice, endangering attachments and the user.

You MUST unplug any load from the generator before starting to prevent permanent damage to any appliances.