can find a control board in the bottom. The lay out of the control board is illustrated below.

JP1

4

3

2

1

 

 

 

 

O

N

2). By switch setting at different positions of JP1, interface selection between RS232 and USB and PID selection can be made.

a.Interface select: switch position 1 of JP1 defines interface of the cash drawer besides the interface cable used. When switch position 1 is ON, the controller responds to RS232 signals. When switch position 1 is OFF, the cash drawer works to USB interface.

b.USB PID select: Switch positions 2, 3 or 4 define a drawer number for the cash drawer as in below table so that this cash drawer is going to respond accordingly in USB communication. Please note that within each system there should never be any 2 USB interface cash drawers carrying the same drawer number.

USB PID

1

2

3

4

5

6

7

0

JP1 SW

 

 

 

 

 

 

 

 

2

ON

ON

ON

OFF

OFF

OFF

OFF

ON

3

ON

OFF

OFF

ON

ON

OFF

OFF

ON

4OFF ON OFF ON OFF ON OFF ON Default setting: Drawer 7 (SW2: OFF; SW3: OFF; SW4: OFF)

UPOS and WEPOS driver application:

Please first find in Posiflex Product Information CDROM or download from Posiflex web sites for UPOS driver setup. In this application CR-2204 responds to OpenDrawer command only; CR-2200/2204 are compliant to UPOS version 1.7 and CR-2205 is compliant to UPOS version 1.8 and is also WEPOS certified.

Part 6

Page 6
Image 6
POSIFLEX Business Machines CR-2200 user manual Upos and Wepos driver application