TRACTOR - - MODEL NUMBER PRK17G42STB

SCHEMATIC

RED

BLACK

BATTERY

 

A

RED

 

 

 

 

AMMETER

 

FUSE

 

 

(OPTIONAL)

 

 

 

WHITE

 

RED

B

S

 

 

M

CLUTCH / BRAKE

 

G

 

 

A1

(PEDAL UP)

 

L

A2

 

BLACK

IGNITION

 

SWITCH

 

 

 

 

 

 

BLACK

 

 

 

BLACK

 

 

 

HOUR

 

 

 

METER

 

 

 

(OPTIONAL)

 

 

 

FUEL

 

 

BLUE

LINE

 

RED

M

 

 

 

 

STARTER

 

 

BLACK

 

SOLENOID

 

 

WHITE

 

 

 

SEAT SWITCH

 

 

(NOT OCCUPIED)

WHITE

 

 

BLACK

BLACK

 

ATT'MENT CLUTCH

GROUNDING

BLACK

(CLUTCH OFF)

CONNECTOR

 

 

 

 

 

 

SPARK

BLACK

 

IGNITION

 

PLUG

 

 

 

UNIT

 

GAP

 

 

(2 PLUGS ON

 

 

 

 

 

 

TWIN CYL. ENGINES)

 

CHARGING SYSTEM OUTPUT

28 VOLTS AC MIN. @ 3600 RPM

 

3 AMP DC @ 3600 RPM

(CHARGING SYSTEM DISCONNECTED)

FUEL SHUT-OFF SOLENOID

RED

 

 

 

 

 

(IF SO EQUIPPED)

LIGHTING SYSTEM OUTPUT

 

 

DIODE

 

ORANGE

5 AMP AC @ 3600 RPM

 

 

ALTERNATOR

14 VOLTS AC MIN. @ 3600 RPM (LIGHTS OFF)

IGNITION SWITCH

POSITION

CIRCUIT

“MAKE”

 

 

 

OFF

M+G+A1

NONE

RUN/LIGHT

B+A1

A2+L

NOTE

YOUR TRACTOR IS EQUIPPED WITH A SPECIAL ALTERNATOR SYSTEM. THE LIGHTS ARE NOT CONNECTED TO THE BATTERY, BUT HAVE THEIR OWN ELECTRICAL SOURCE. BECAUSE OF THIS, THE BRIGHTNESS OF THE LIGHTS WILL CHANGE WITH ENGINE SPEED. AT IDLE THE LIGHTS WILL DIM. AS THE ENGINE IS SPEEDED UP, THE LIGHTS

WILL BECOME THEIR BRIGHTEST.

WIRING INSULATED CLIPS

BROWN

BLACK

HEADLIGHTS

NON-REMOVABLE

CONNECTIONS

REMOVABLE

CONNECTIONS

RUN

B+A1

NONE

START

B + S + A1

NONE

NOTE: IF WIRING INSULATED CLIPS WERE REMOVED FOR SERVICING OF UNIT, THEY SHOULD BE REPLACED TO PROPERLY SECURE YOUR WIRING.

27

Page 27
Image 27
Poulan 178108 owner manual Tractor - Model Number PRK17G42STB, Schematic