Poulan EBV 210 instruction manual Select An Extension Cord, Stopping Your Unit, Starting Your Unit

Models: EBV 210

1 10
Download 10 pages 23.47 Kb
Page 7
Image 7
SELECT AN EXTENSION CORD

NOTE: If you are unable to locate the inlet restrictor, the unit will still operate. This restrictor improves the blower function.

SClose the inlet cover and make sure it is latched closed.

S Re-install the blower tube. Refer to

ATTACHING THE BLOWER TUBE for

instructions on how to attach this item.

SELECT AN EXTENSION CORD

Use only a 120 A.C. voltage supply as shown on nameplate of the unit to power your blower.

DTo reduce the risk of electrical shock, this equipment has a polarized plug (one blade is wider than the other) and will require the use of a polarized extension cord. The appliance plug will fit into a polarized extension cord only one way. If the plug does not fit fully into the extension cord, reverse the plug. If the plug still does not fit, obtain a correct polarized extension cord. A polarized extension cord will require the use of a polarized wall outlet. This plug will fit into the polarized wall outlet only one way. If plug does not fit fully into the wall outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper wall outlet. Do not change the equipment plug, extension cord receptacle, or extension cord plug in any way.

The extension cord used to reach the power source must be:

DSpecifically marked as suitable for out- door use. The cord must be marked with the suffix “W-A” (in Canada “W”).

DHeavy enough to carry full current from the power source to the unit. Otherwise, loss of power and overheating can oc- cur causing damage to unit. Refer to table for minimum wire gauge recom- mendations. The cord must be marked with the proper wire gauge. (Appropriate

extension cords are available.) Do not use multiple cords.

DIn good condition. Cord insulation must be intact with no cracks or deterioration. Plug connectors must be undamaged. DO NOT use multiple cords.

MINIMUM WIRE GAUGE

RECOMMENDATIONS

VOLTS

25 FT.

50 FT.

100 FT.

 

 

 

 

120

16

16

14

 

A.W.G.*

A.W.G.*

A.W.G.*

 

 

 

 

*American Wire Gauge

Secure the extension cord to the unit by threading the cord through the cord re- tainer (see illustration). Insert the cord receptacle into the recessed plug.

Cord Receptacle

Recessed Plug STOPPING YOUR UNITSTARTING YOUR UNITOPERATING POSITIONManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background on Unit

Cord

Retainer

Manual background WARNING: You MUST make sure the tubes are secure before using the unit.

Manual background WARNING: Do not use the unit without the tubes or collection bag properly attached to avoid flying debris and/or impeller contact which can cause serious injury. Always wear eye protection to prevent rocks or debris from being blown or ricocheting into the eyes and face which can result in blindness or serious injury.

STOPPING YOUR UNIT

Slide the ON/OFF switch to the OFF position.

STARTING YOUR UNIT

Your unit has two run positions, LOW and HIGH. Slide the switch to one of these positions to turn on the unit.

OPERATING POSITION

Eye Protection

Eye Protection

 

 

 

 

 

 

 

 

Blower

Vacuum

7

Page 7
Image 7
Poulan EBV 210 instruction manual Select An Extension Cord, Stopping Your Unit, Starting Your Unit, Operating Position