Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
Features
•Guaranteed low oil carryover rate of less than 2 PPM
•Three year warranty on compressor pump
•High efficiency motors
•UL listed controls
•R134A Air Dryer (Optional)
The
The units consist of two equally rated
Compressor assemblies are available with or without a factory mounted basic or deluxe alternator/motor starter package. An unloading feature is included on all compressors to provide loadless starting. Models with an alternator are prewired and ready for operation. Internal wiring allows for shutdown of either compressor for repair while the other compressor is running.
An alternating type operation is desirable for many reasons. When a duplex air compressor is alternated, the temperature of both units is kept above the ambient dew point to minimize moisture deterioration and corrosion. Also, the reduction in on- time provides a lower average head temperature with reduced oil entrainment potential and improves the motor life by holding down the average heat rise.
Figure 1 -
with Optional Deluxe Alternator Package
Specifications
| Product |
|
| ||
| Performance |
|
|
|
|
| Specifications |
|
| See Table 1 | |
| Models & Options |
|
| See Table 2 | |
|
|
|
|
|
|
| Lubrication |
| 1/2 Through |
|
|
|
|
| 10 Hp Models | Splash Lubrication System | |
|
|
|
|
|
|
| Operating | 1Ø | 115/230 Volts, 60 Hz | ||
|
|
|
|
|
|
| Voltages | 3Ø | |||
| Compression |
| 1/2 Through |
|
|
| Cycle |
| 10 Hp Models |
| |
| Motor Overload |
| 1Ø and 3Ø | Overloads (Supplied with all Factory Mounted | |
| Protection |
|
| Alternators; Otherwise Field Supplied) | |
|
|
| Lead | ||
| Pressure Switch |
|
| ||
| Settings |
| Lag | ||
|
|
|
|
| |
| Overpressure |
|
| ASME Safety Valve Factory Set and Sealed at | |
| Protection |
|
| Approximately 115 psig (805 kPa) | |
|
|
|
|
|
|
| Outlet Air |
|
| 1/2" NPT on 30 and 80 Gallon Tanks; | |
| Connections |
|
| 1" NPT on 120, and 200 Gallon Tanks | |
|
|
|
|
|
|
| Tank Sizes |
|
| See Table 2 |
|
| California |
|
|
|
|
| Ordinance 462 (L)(2) |
|
| Meets requirements of this Ordinance | |
| Isolation Mounts |
|
| Vibration pads are included with each unit |