Climate Control Simplex

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.

Features

Guaranteed low oil carryover rate of less than 2 PPM

Three year warranty on compressor pump

Isolation pads

Optional R134 dryer

ASME tank

UL listed controls

The AS-XXX Series Powerex Simplex Air Compressors have been designed, broken -in and tested to meet the most demanding specifications in the pneumatic climate control industry for low oil carryover and long life.

All Powerex air compressors have reliable operation and feature high quality construction and components. An unloading feature is included on all compressors to provide loadless start- ing. Oil entrainment is minimized by the use of lap joint piston rings, low compressor speeds and a special lubricating oil with a high flash point and low carbon content.

All 1/2 through 10 hp models are also equipped with an auxiliary cooling fan and air control shroud to achieve low head temperatures and further minimize oil carryover.

Powerex compressor motors are NEMA Class B design. Single-phase motors have built-in overload protection and a DPST disconnect switch. Three-phase motors require a manual or magnetic starter and three overload heater coils which may be ordered as a factory mounted and wired option.

Figure 1 - AS-XXX 1 Hp Simplex Air Compressor

 

 

 

Specifications

 

 

 

 

 

 

 

Product

 

AS-XXX Series Powerex Simplex Air Compressors

 

 

Performance

 

 

 

 

Specifications

 

See Table 1

 

 

Models & Options

 

See Table 2

 

 

 

 

 

 

 

Lubrication

1/2 Through 10

Splash Lubrication System

 

 

Operating

115 - 208/230 Volts, 60 Hz

 

 

Voltages

208-230/460 Volts, 60 Hz

 

 

Compression

1/2 Through

 

 

 

Cycle

10 Hp Models

Single-Stage

 

 

 

 

 

 

 

Motor Overload

Built-In Thermal Overload (Standard)

 

 

Protection

Magnetic Starter and Three Thermal Overload

 

 

 

 

Switches (Optional)

 

 

Pressure Settings

 

Cut-In: Factory Set at Approximately 70 psig (490kPa)

 

 

 

 

Cut-out: Factory Set at Approximately 90 psig (630 kPa)

 

 

 

 

 

 

 

Overpressure

 

ASME Safety Valve Factory Set and Sealed at

 

 

Protection

 

Approximately 115 psig (805 kPa)

 

 

Outlet Air

 

1/2" NPT on 30, 60 and 80 Gallon Tanks;

 

 

Connections

 

1" NPT on 120 and 200 Gallon Tanks

 

 

 

 

 

 

 

Tank Sizes

 

See Table 2

 

 

California

 

 

 

 

Ordinance 462

 

Meets Requirements of this Ordinance

 

 

(L) (2)

 

 

 

 

 

 

 

 

 

Tank Isolation

 

Standard All Units

 

 

Manuals

 

200 Page Service Manual Available

 

 

 

 

 

 

The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult the local Powerex office. Powerex shall not be liable for damages resulting from misapplication or misuse of its products.

Powerex • 150 Production Drive • Harrison, OH 45030 • USA

IN259601AV 10/04