Climate Control Simplex

TABLE 1: AS-XXX SERIES POWEREX SIMPLEX AIR COMPRESSORS

PERFORMANCE SPECIFICATIONS

 

Base

Actual Hp

Motor Rating

Compressor

Compressor Capacity ACFM*

 

Model

Hp

RPM

RPM

100% Runtime

50% Runtime

33% Runtime

 

AS-105

.54

1725

800

1.8

0.9

0.6

 

 

 

 

.54

1720

 

 

AS-005

.54

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AS-107

.73

1725

1040

2.5

1.25

0.83

 

 

AS-007

.73

.73

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AS-110

1.07

1725

625

3.8

1.9

1.25

 

 

AS-010

1.07

1.07

 

 

 

 

 

 

 

 

 

AS-015

1.54

1.54

1750

955

6.4

3.2

2.11

 

 

AS-020

2.0

2.0

1750

800

8.6

4.3

2.84

 

 

 

 

 

 

 

 

 

 

 

 

 

AS-030

3.1

3.1

1745

775

12.0

6.0

4.0

 

 

AS-050

5.6

5.6

1745

690

22.0

11.0

7.33

 

 

 

 

 

 

 

 

 

 

 

 

 

AS-075

8.2

8.2

1745

795

28.5

14.3

9.44

 

 

AS-100

10.3

10.3

1750

685

43.0

21.5

14.2

 

 

 

 

 

 

 

 

 

 

 

 

Mounted and Connected Options

MAGNETIC MOTOR STARTER

An optional magnetic motor starter which has been selected and wired for the intended input voltage is available for all units. All starters are furnished with properly sized overload heaters.

REFRIGERATED AIR DRYER

A factory mounted Model Hankinson HPR 5-10 Series refrigerated air dryer with automatic condensate drain trap assembly, bypass valve is available as an option on all 1/2 through 3 Hp Powerex Simplex air compressors. Piping for air dryer is done at the factory. Wiring to power source must be done in the field using integral cord and plug which fits into a standard 120 volt receptacle. Refer to Table 2 for ordering details.

AUTOMATIC TANK DRAIN

Powerex air compressors are ordered with either a manual or electric type automatic tank drain. This unit is furnished with a manual drain attach- ment.

VIBRATION DAMPENING PADS

Waffle type design vibration pads are provided as standard equipment.

Operation

Factory calibrated snap-acting DPST pressure electric switches provide automatic cut-in and cut-out. Overpressure protection is provided by an ASME safety relief valve. Receiver tanks have a condensate drain valve with an extension for easy access. All mounting bases are slotted for V-belt tension adjustment to aid in maintaining proper compressor and motor alignment.

All units are run through the factory break-in and are tested for air delivery, leakage and power consumption.

Units are shipped with a proper fill of compressor oil in the crankcase and are furnished with an intake filter/silencer with a replaceable cartridge. This fil- ter/silencer combination is designed to remove contaminates in the inlet air and provide quieter operation. The 5 through 10 Hp models are complimented by this design utilizing dual element filtration which consists of a pleated element and a foam element for filtration against larger particles from the atmosphere.

LUBRICATION

Check lubricating oil level at gauge. Refill if necessary.

Change oil according to maintenance schedule. Before draining oil, remove oil supply cap and loosen oil drain cap

to release trapped air. Use Mobil Rarus 427® or Mobil DTE heavy oils.

Dispose of oil in ! WARNING accordance with

state or local codes.

Remove cap and use funnel to add oil.

Oil drain

Oil gauge

cap

 

Round (red)

 

 

Full

 

Low

OIL GAUGE

Figure 2 - Lubrication

2