Medical Package System

BEFORE START UP

1.Make sure all safety warnings, labels and instructions have been read and understood before continuing.

2.Remove any shipping materials, brackets, etc.

3.Confirm that the electric power source and ground have been firmly connected.

4.Be sure all pressure connections are tight.

5.Check to be certain all safety relief valves, etc., are correctly installed.

6.Check that all fuses, circuit breakers, etc., are the proper size.

7.Make sure the inlet filter is properly installed.

8.Confirm that the drain valve is closed.

9.Visually check the rotation of the compressor pump. If the rotation is

incorrect, have a qualified electrician correct the motor wiring.

START-UP AND OPERATION

1.Follow all the procedures under

“Before start-up” before attempting operation of the compressor.

2.Switch the electric source breaker on.

3.Both dryers should be plugged in and set at the on position.

4.Dewpoint & CO Monitors should be on and the sampling valves open. Calibrate Dewpoint and CO per enclosed manufacturer’s instructions.

5.Ensure water lines are properly installed to water-cooled aftercoolers. Turn on water.

IMPORTANT: This is not a standard option. Check to see if water-

cooled aftercoolers were provided.

6.Compressor unit isolation valves are preset at the factory in the open position except for tank by-pass which must remain closed during normal operation.

7.Dryer and filter isolation valves: Valves should be open to one dryer and one filter bank.

8.Close valve leading to the Medical Air System from receiver on the compressor unit.

a.Turn both fusible/breaker disconnects to the on position. Low pressure alarm will sound. Silence the alarm by pushing alarm acknowledge button.

b.Jog each compressor in the manual position on the selector switch to check for rotation. (Clockwise if

Medical

Air Schematic

Specifications

Medical Package Duplex – Model MPD

MODEL

HP

PHASE

SCFM

SCFM

RPM

VOLTAGE

FULL LOAD AMP/

GALLON

DIMENSION

SHIPPING

@100 PSIG

@ 50 PSIG

MOTOR

TANK

LxWxH

WT. (Lbs.)

MPD0508

5(2)

3

33.4

36.2

870

208/230/460

17.4 / 16.5 / 8.2

120

64 x 65 x 76

1288

 

 

 

 

 

 

 

 

 

 

 

MPD0758

7.5(2)

3

52.2

55.1

840

208/230/460

23.4 / 22 / 11

120

64 x 65 x 76

1340

 

 

 

 

 

 

 

 

 

 

 

MPD1008

10(2)

3

70

76.3

1070

208/230/460

29 / 33 / 16.5

200

64 x 65 x 80

1510

 

 

 

 

 

 

 

 

 

 

 

MPD1508

15(2)

3

108.4

114.1

1250

208/230/460

51 / 48 / 24

200

64 x 65 x 80

1630

 

 

 

 

 

 

 

 

 

 

 

Medical Package Triplex – Model MPT

MODEL

HP

PHASE

SCFM

SCFM

RPM

VOLTAGE

FULL LOAD AMP/

GALLON

DIMENSION

SHIPPING

@100 PSIG

@ 50 PSIG

MOTOR

TANK

LxWxH

WT. (Lbs.)

MPT0508

5(3)

3

50.1

54.7

870

208/230/460

17.4 / 16.5 / 8.2

200

96 x 65 x 80

1838

 

 

 

 

 

 

 

 

 

 

 

MPT0758

7.5(3)

3

78.8

83.9

840

208/230/460

23.4 / 22 / 11

200

96 x 65 x 80

1980

 

 

 

 

 

 

 

 

 

 

 

MPT1008

10(3)

3

105

111.5

1070

208/230/460

29 / 33 / 16.5

240

96 x 65 x 92

2160

 

 

 

 

 

 

 

 

 

 

 

MPT1508

15(3)

3

162.6

168

1250

208/230/460

51 / 48 / 24

240

96 x 65 x 92

2280

 

 

 

 

 

 

 

 

 

 

 

Medical Package Quadplex – Model MPQ

 

MODEL

HP

PHASE

SCFM

SCFM

RPM

VOLTAGE

FULL LOAD AMP/

GALLON

DIMENSION

SHIPPING

 

 

@100 PSIG

@ 50 PSIG

MOTOR

TANK

LxWxH

WT. (Lbs.)

 

 

MPQ0508

5(4)

3

66.8

74.9

870

208/230/460

17.4 / 16.5 / 8.2

240

128 x 65 x 92

2388

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MPQ0758

7.5(4)

3

104.4

120.2

840

208/230/460

23.4 / 22 / 11

240

128 x 65 x 92

2490

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MPQ1008

10(4)

3

140

153

1070

208/230/460

29 / 33 / 16.5

240

128 x 65 x 92

2640

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MPQ1508

15(4)

3

216.8

221

1250

208/230/460

51 / 48 / 24

240

128 x 65 x 92

2735

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4