Medical Package System
facing the black fan shroud and counterclockwise if facing the compressor flywheel.)
c.Set both selector switches to the auto position. Compressors will both run until the lead pressure switch closes.
d.Open valve at the air receiver leading to Medical Air System.
e. Check for air leaks at the connections.
9.Check that the compressor operates without excessive vibration, unusual noises or leaks.
10.Check the discharge pressure. Also make sure the air pressure rises to the designated pressure setting by checking the discharge pressure gauge.
11.Check the operation of the pressure switch or the pilot valve for continuous run units by opening the stop valve and confirming the compressor starts or reloads as pressure drops.
QUADPLEX MPQ | DUPLEX MPD | DRYER SYSTEM | FILTER SYSTEM |
|
| MDR OR MDD | MFP |
++
TRIPLEX MPT
32" | 32" | 32" | 8" |
LEFT | Consult factory |
| RIGHT |
END |
| END | |
for special voltages |
| ||
VIEW |
| VIEW | |
or arrangements. |
| ||
|
|
|
COMPRESSOR MAINTENANCE SCHEDULE
|
|
|
| Operating Hours |
|
|
| |
Item | Action needed | 500 | 2500 | 5000 | 10,000 | 15,000 | 20,000 | Remarks |
Tank | Drain moisture | Daily | 2500 |
|
|
|
|
|
Inlet air filter | Replace | ● | ▲ | (Every 2,500 hrs or less) |
|
| ||
Blower fan | Clean |
|
| ● | ● | ● | ● |
|
Fan Duct | Clean |
|
| ● | ● | ● | ● |
|
Compressor Fins | Clean |
| ● | (Every 2,500 hrs or less) |
|
| ||
Bearings | Replace |
|
|
| ● | ● | ▲ |
|
Compression rings | Replace |
|
|
| ▲ |
| ▲ |
|
Wrist pin bearing | Regrease |
|
|
| ▲ |
| ▲ |
|
Piston set | Replace |
|
|
|
|
| ▲ |
|
Inspect, replace | *Note 3 | ● | ▲ | ▲ | ▲ | ▲ |
| |
Safety valve | Confirm operation |
| ● | (Every 2,500 hrs or less) |
|
| ||
Pressure gauge | Inspect |
| ● | (Every 2,500 hrs or less) |
|
| ||
|
|
|
|
|
|
|
|
|
Air leaks | Inspect |
| ● |
| ● |
| ● |
|
Filters | Replace |
| ▲ | ▲ | ▲ | ▲ | ▲ (View delta pressure | |
Moisture drains | Inspect | ● |
| ● |
| ● | indication) | |
|
|
|
| |||||
traps |
|
|
|
|
|
|
|
|
Suction pressure |
| ● | ● | ● | ● | ● |
|
|
(refrigerated) |
|
|
|
|
|
|
|
|
Heat exchanger |
| ● | ● | ● | ● | ● |
|
|
●Inspect ▲ Replace
1.Inspect and perform maintenance periodically according to maintenance schedule.
2.The maintenance schedule relates to the normal operating conditions. If the circumstances and load condition are adverse, shorten the cycle time and do maintenance accordingly.
3.* The tension of the
5