Scroll Air Compressors
Orbit Scroll Bearings
Housing
Side Bearings
Grease Fitting
Extension | Needle | |
Adaptor | ||
Adaptor | ||
|
Figure 4 | Figure 5 | |
| ||
|
|
|
|
|
|
Maintenance Schedule |
|
|
|
|
|
|
| Operating Hours |
|
|
| |
| Item | Action needed |
| 500 | 2500 | 5000 | 10,000 | 15,000 | 20,000 | Remarks |
|
|
|
|
|
|
|
|
|
|
|
| Tank | Drain moisture |
| Daily |
|
|
|
|
|
|
| Inlet air filter | Replace |
| ● | ▲ | (Every 2,500 hrs or less) |
| Part #IP032901AV | ||
| Blower fan | Clean |
|
|
| ● | ● | ● | ● |
|
|
|
|
|
|
|
|
|
|
|
|
| Fan Duct | Clean |
|
|
| ● | ● | ● | ● |
|
| Compressor Fins | Clean |
|
| ● | (Every 2,500 hrs or less) |
|
| ||
| Bearings | Regrease | (Every 5,000 hours for 145 psig scroll) | ● |
| ▲ | Service Center Only | |||
|
|
|
|
|
|
|
| |||
| Tip seal set | Replace | (Every 5,000 hours for 145 psig scroll) | ▲ |
| ▲ |
| |||
| Inspect, replace |
| *Note 3 | ● | ▲ | ▲ | ▲ | ▲ |
| |
| Pressure Switch | Confirm operation |
|
|
| ● |
| ● |
| |
|
|
|
|
|
|
|
|
|
|
|
| Magnetic starter | Inspect |
|
|
|
| ● |
| ● | Replace if contact |
|
|
|
|
|
|
|
|
|
| points deteriorated |
| Safety valve | Confirm operation |
| ● | (Every 2,500 hrs or less) |
|
| |||
| Pressure gauge | Inspect |
|
| ● | (Every 2,500 hrs or less) |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| ● | Inspect |
|
|
|
|
|
|
|
|
| ▲ | Replace |
|
|
|
|
|
|
|
|
NOTES:
1.Inspect and perform maintenance periodically according to maintenance schedule.
2.The maintenance schedule relates to the normal operating conditions. If the circumstances and load condition are adverse, shorten the cycle time and do maintenance accordingly.
3.* The tension of the
4.See Compressor Pump Manuals for replacement or service procedures.
3