Guide Specifications

Nominal

 

Nominal

250 fpm

375 fpm

500 fpm

625 fpm

Media

Weight

Depth

Efficiency

Size

 

 

 

 

 

 

 

 

Area

Each

cfm

pd

cfm

pd

cfm

pd

cfm

pd

(inch)

 

HxWxD

(sq.ft.)

(lbs.)

 

 

(inch)

 

 

 

 

 

 

 

 

 

 

12

65%

24x24x12

1000

.20

1500

.35

2000

.45

2500

.57

140

26

24x12x12

500

750

1000

1250

69

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

95%

24x24x12

1000

.25

1500

.45

2000

.65

2500

.78

140

27

24x12x12

500

750

100

1250

69

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

1.PD represents clean pressure drop in inchw.g. The recommended final pressure drop is 1.5 inch w.g.

2.Operation down to zero velocity is satisfactory for all models.

3.Performance tolerances conform to section 7.4 of ARI Standard 850.

4.Performance values stated may be averages typical of the products listed. Contact factory for actual performance test reports on specific products.

5.Perfmormance values shown in this publication may be averages or estimates intended to generally represent product styles. Always contact factory for latest actual test data on specific Flanders Precisionaire models.

Guide Specifications

1.0

General

2.4

Corrosion-resistant steel expanded metal face-

1.1

Medium and high efficiency gas turbine rigid fil-

 

guards shall be installed on the air entering and

 

leaving sides.

 

ters shall be PrecisionCell GT extended media

 

 

 

 

 

separator type filters as manufactured by

2.5

1/2” corrosion-resistant steel “T” straps shall be

 

Flanders.

 

installed on the air leaving side and horizontal

1.2

Filter sizes, efficiencies and capacities shall be

 

strap on air entering side.

 

 

 

as scheduled on the drawings.

2.6

Filters shall be UL 900 Class 1 listed.

2.0

Filter Construction

3.0

Performance

2.1

Filters shall be constructed by pleating a con-

3.1

Initial and final resistance shall not exceed the

 

tinuous sheet of moisture-resistant dual layer,

 

scheduled values.

 

wet-laid micro-fine glass media into closely

3.2

Media area must equal or exceed that of the

 

spaced pleats with hemmed-edge corrugated

 

 

specified filter.

 

aluminum separators.

 

 

3.3

The average efficiency shall be as determined

2.2

The filter pack shall be compression sealed into

 

by the ASHRAE Standard 52.1 and 52.2 test

 

a 24 ga. corrosion-resistant steel frame.

 

 

 

methods.

 

 

 

2.3

The enclosing frame shall be assembled in a

3.4

The manufacturer shall guarantee performance

 

 

rigid manner and shall incorporate a single or

as stated in the literature within tolerances as

double header as required by job conditions.

outlined in section 7.4 of ARI Standard 800.

 

Flanders PrecisionAire

Foremost in Air Filtration

Toll Free: 1-800-637-2803

REPRESENTED BY:

Page 2