14Basic Operation Instructions
Fault | Probable Cause(s) | Possible Solution | |
Code |
|
| |
1 | Flash | The batteries need charging. | Check the battery connections. If the |
|
| There is a bad connection | battery connections are good, then |
|
| to the batteries. | try charging the batteries. |
|
|
|
|
2 | Flashes | There is a bad connection on | Check the left motor connections and |
|
| the left motor. | wiring harnesses. |
|
|
|
|
3 | Flashes | The left motor has a short to | Contact your authorized Pride |
|
| a battery connection. | Provider. |
|
|
|
|
4 | Flashes | There is a bad connection on | Check the right motor connections |
|
| the right motor. | and wiring harnesses. |
|
|
|
|
5 | Flashes | The right motor has a short to | Contact your authorized Pride |
|
| a battery connection. | Provider. |
|
|
| |
6 Flashes | The charge inhibit has been | Make sure that the battery charger | |
|
| activated. | is not connected to the power base. |
|
|
|
|
7 | Flashes | There is a joystick fault. | Make sure the joystick is in the center |
|
|
| position and then power off and on |
|
|
| again. |
|
|
|
|
8 | Flashes | There is a control system fault. | Check power module and joystick |
|
|
| module connections and wiring. |
|
|
|
|
9 | Flashes | The park brakes have a bad | Check the left and right motor |
|
| connection. | connections and wiring. |
|
|
| |
10 Flashes | An excessive voltage has | Check the battery connections. | |
|
| been applied to the control |
|
|
| system. |
|
|
|
|
|
CARE AND MAINTENANCE
Refer to your power chair owner’s manual for proper cleaning and disposal instructions.
WARRANTY
For two (2) years from the date of purchase, Pride will repair or replace at our option to the original purchaser, free of charge, the controller or any of its components found upon examination by an authorized representative of Pride to be defective in material and/or workmanship.
GC Controller | www.pridemobility.com |