INSTALLATION

Positioning

Remove all the packaging and install the cooker in a dry well, ventilated room away from curtains, paper, alcohol, petrol etc. (See figure).

This appliance is approved to class “1” regarding overheating of surrounding surfaces.

It is mandatory to keep 20 mm distance from the adjacent furniture.

L.P.G. cookers or ovens MUST NOT be installed below ground level, i.e. in a basement, or aboard any boat, yacht or other vessel.

660 mm

Proline

1 G

2

3

4

5678

20 mm

150 mm

610 mm

20 mm

The cooking appliance must be fitted with a stability chain firmly secured to the wall (see fig)

Ventilation

The room containing the cooker should have an air supply in accordance with B.S. 5440: Part 2: Current Editions.

The following requirements for ventilation must be met.

The cooker should not be installed in a bed sitting room with a volume of less than 20m3, if it is installed in a room of volume less 5m3 an air vent of effective area of 110cm2 is required; if it is installed in a room of volume between 5m3 and 10m3, an air vent of effective area 50cm2 is required, while if the volume exceeds 11m3 no air vent is required. However, if the room has a door, which opens directly to the outside, no air vent is required even when the volume is between 5m3 and 11m3.

Fitting the adjustable feet

Unpack the support brackets with the feet attached.Place a piece of cloth/cardboard onto your floor to protect both your floor and the cooker.

Lay the cooker on its back, fit the support brackets (see fig) using the bolts, washers and nuts supplied and ensure that the nuts are tight. lift the cooker upright onto its feet.

Stability

hook

Firmly fix chain to rear of cooker

 

 

Chain to be as

 

 

short as

Stability

 

practicable

chain

 

 

 

 

 

 

 

If there are other fuel burning appliances in the same room, B.S. 5440: Part. 2: Current Editions should be consulted to determine the requisite air vent requirements.

Location

The cooker may be located in a kitchen, a kitchen/diner or bed sitting room but not in a bathroom, shower room or garage.

For information regarding the fitting of flexible supply pipes, the highest temperature at the rear of this cooker which may come into contact with the supply pipe is 70°C above ambient.

L.P.G. cookers or ovens MUST NOT be installed below ground level, i.e. in a basement, or aboard any boat, yacht or other vessel.