PVI Industries 2000N600A-TPO dimensions Turbopower Gas/Oil, Packaged Water Heater, PV 5460 03/04

Models: 750N600A-TPO 3500N600A-TPO 3000N600A-TPO 4000N600A-TPO 1250N600A-TPO 1000N600A-TPO 500N600A-TPO 2500N600A-TPO 2000N600A-TPO 1500N600A-TPO

1 1
Download 1 pages 4.06 Kb
Page 1
Image 1
TURBOPOWER® GAS/OIL

 

 

TURBOPOWER® GAS/OIL

PACKAGED WATER HEATER

 

 

 

 

NICKELSHIELD® NICKEL-PLATED STORAGE TANK

 

 

 

 

 

 

 

 

 

 

TANK SERIES 600 GALLONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Recovery gph

 

 

Min. Inlet Flow

 

Dimensions (inches)

 

Blower

Shipping

 

Model

Input

#2 Oil

 

Motor

 

Number

 

 

Btu/h

Gas Pressure

gph

 

 

 

 

 

 

 

 

Weight

 

 

 

 

 

 

 

 

 

 

Volt/Ph/

 

40°- 120°F

40°- 140°F

"W.C.

 

A

B

C

 

J

HP

 

lbs

 

 

 

 

 

 

 

 

Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

750

N 600A-TPGO

750

600

600,000

4.5

 

4.3

46

6

1

 

31

1/2

 

115/1/10

2720

1000

N 600A-TPGO

1000

800

800,000

6.0

 

5.7

46

8

1

 

31

1/2

 

115/1/10

2760

1250

N 600A-TPGO

1250

1000

1,000,000

7.5

 

7.2

54

8

1

 

31

3/4

 

115/1/14

2850

1500

N 600A-TPGO

1500

1200

1,200,000

7.5

 

8.6

54

8

1-1/4

 

31

1

 

115/1/16

2930

2000

N 600A-TPGO

2000

1600

1,600,000

6.5

 

11.4

63

10

2

 

36

2

 

115/1/24

3140

2500

N 600A-TPGO

2500

2000

2,000,000

8.0

 

14.3

65

10

2

 

36

2

 

115/1/24

3260

Recoveries based on 83% thermal efficiency. ASHRAE 90.1 compliant for efficiency and standby loss. "J" dimension is for the burner housing only. Gas train may exceed this dimension.

Standard gas train.

*The information presented is for Natural gas 0.6 S.G.— For operation with propane (LP gas), consult factory. Dimensions are in inches unless otherwise specified.

Higher inputs available. Consult the factory.

For standard and optional equipment, see form PV 6046.

*GAS PRESSURE REQUIREMENTS

SEE TABLE FOR MINIMUM PRESSURE BY MODEL NUMBER.

MAXIMUM STATIC INLET PRESSURE: 14" W.C.

FOR PRESSURES OTHER THAN LISTED, CONSULT FACTORY.

Pressure shown is for standard UL gas train. Additional controls

may increase pressure requirements.

VENTING REQUIREMENTS

-.02" TO -.06" W.C. (NEGATIVE PRESSURE)

ENTIRE VENT SYSTEM SHOULD NEVER BE SIZED BASED UPON THE VENT CONNECTION DIAMETER EXCLUSIVELY.

FOR PROPER SIZING, CONSULT
THE NATIONAL FUEL GAS CODE UNDER “FAN-ASSISTED.”
*REAR ACCESS MODULE

MODEL PREFIX

M

L

STD or OPTIONAL

 

 

 

 

750-1500

23"

8"

OPTIONAL

 

 

 

 

2000-2500

23"

16"

STANDARD

 

 

 

 

STANDARD ELECTRICAL REQUIREMENTS

CONTROL VOLTAGE: 120V, 1Ø, 60 HZ., 2 AMPS.

MOTOR VOLTAGE:

208V, 230V, AND 460V MOTORS ARE AVAILABLE BUT WILL REQUIRE A SEPARATE 120V/2 amps CONTROL CIRCUIT OR AN OPTIONAL CONTROL CIRCUIT TRANSFORMER.

PVI RESERVES THE RIGHT TO CHANGE THE DESIGN

AND SPECIFICATION WITHOUT NOTICE.

PVI INDUSTRIES, LLC

FORT WORTH, TEXAS 76111

PV 5460 03/04

(800) 784-8326 (817) 335-9531 www.pvi.com

Product is patented in the U.S., Canada, and Mexico.

 

 

Page 1
Image 1
PVI Industries 2000N600A-TPO dimensions Turbopower Gas/Oil, Packaged Water Heater, Nickelshield Nickel-Platedstorage Tank