OPE RATION:
1INSERT AC POWER PLuG INTO A IIOV VOLT AC OUTLET.
2CONNECT THE POWER CORD OF YOUR EQUIPMENT (13.5V - 14 1VDC) TO THE OUTPUT BINDING POST TERMINALS ON THE FRONT OF THE UNIT BE SURE THAT POLARITY IS CORRECT. THE RED POSITIVE (+) TERMINAL AND BLACK NEGATIVE
EQUIPMENT.
3TURN SWITCH TO "ON". RED LIGHT IN SWITCH WILL ILLUMINAfE
4THE INPUT POWER IS PROTECTED BY THE FUSE WHICH IS LOCATED AT THE REAR
OF THE UNIT AND CAN BE REPLACED BY UNSCREWING THE FUSE HOLDER IF THE FUSE IS BURNT OUT. DO NOT USE A FUSE LARGER THAN • • AMPS USE OF HEAVIER FUSE MAY RESULT IN DAMAGING TO THIS UNIT ( • • SEE NOTE)
5.THIS UNIT HAS ELECTRONIC OVERLOAD PROTECTION WITH INSTANT AUTOMATIC
RESET FUNCTION IF OUTPUT IS OVERLOADED. THE OUTPUT POWER WILL AUTOMATICALLY SHUT OFF. RELEASE POWER CORD Of YOUR EQUIPMENT FROM
THE OUTPUT TERMINALS AND CHECK THE ACTUAL POWER RATING OF YOUR EQUIPMENT. THIS UNIT WILL AUTOMATICALLY RESET INSTANTLY
6. | OVER TEM PERATURE | PROTECTION CIRCUITRY IS USED IN | |
| TO PREVENT OVER HEAT DAMAGE UNIT | WI LL BE SHUT DOWN | |
| MINUTES AFTER 15 | MINUTES( M IN. ) AT | 100% RATED LOAD. |
25MINUTES( MIN.) AT 00% RATED LOAD.
NOTE | AM P | |
| : 1 0 | AMP |
| AMP | |
| : 1.5 | AMP |
CAUTIONS: |
|
|
1DO NOT USE WITH EQUIPMENT REQUIRING MORE THAN RATING AMPS
2DO NOT USE OUTDOORS. DO NOT EXPOSE UNIT TO RAIN. MOISTURE. WATER OR
ANY OTHER LIQUIDS
3DO NOT REMOVE COVER IN ANY CASE. RETURN TO DEALER FOR REPAIR IF DAMAGED.
4.THIS UNIT HAS A SPECIAL
"DANGER" HIGH VOLTAGE REFER TO QUALIFIED TECHNICIAN FOR SERVICE_