Specifications
5.25" x 19" x 14"
85 VAC - 260 VAC, 50/60 Hz
(1) 6 ft. (2m) UL/CSA line cord
(1) User Manual
(1) Software Diskette, 3.5" HD
(1) Rocker Switch
(1) Momentary Push Button
(6 or 8) Momentary Push Button
(1) Rotary Potentiometer
(2) Test Point Jacks
(1) Slide Switch
(1) Momentary Push Button
(1) Green LED
(1) Green LED and (1) Yellow LED (6 or 8) Green LEDs
(13 or 20) Yellow LEDs
(1) Red LED
(1) Red LED
(2 or 3) Rotary Trimpots
(1) Slide Switch
(1) 25-pin female D-sub connector
(8, 11 or 15) 15-pin female high-densityD-sub connectors
(1) 9-pin female D-sub connector
(1) 6 terminal screw-terminal connector
(1) 9-pin male D-sub connector
(1) IEC style with fuse
Active Balanced 20k ohms
+14.2 dBu (4.0 Vrms)
+18.2 dBu (6.4 Vrms)
24 bit delta-sigma 128x oversampled Hardwire pass-through to DataPort outputs (via Surround-EX Insert)
0 dB to –18 dB in 0.1 dB steps
99 dB
0.02%
20 Hz – 20 kHz (no filtering)
24 bit delta-sigma 128x oversampled
24 bit digital IIR filters

DCM

Specifications

The QSC DCM acts as the interface between a cinema film audio processor and the power amplifiers in a bi-amp or tri-amp cinema sound system. The DCM performs two major functions: automatic and manual monitoring of processor and amplifier signals, and fully programmable crossover/EQ filtering.

Dimensions (HWD):

Line Voltage Requirements: Accessories Included:

Front Panel Controls

Power Switch:

Monitor Mode Select:

Monitor Channel Select:

Monitor Volume:

Test Lead Connections:

Bypass Mode Select Switch:

Diagnostics Button:

Indicators:

Power Indicator:

Monitor Mode Indicators:

Processor Channel Indicators:

Amplifier Channel Indicators:

Load Fault Indicator:

Clip Indicator:

Rear Panel Controls

Bypass Crossover Level:

Surround EX Mode Switch:

Rear Panel Control Connectors:

Input:

Amplifier DataPorts:

RS232 Serial Port:

Powered Sub/Hearing:

Impaired Output:

Surround EX Insert Point:

AC Power Inlet:

DCM Inputs

Screen Channels and Subwoofer: Input Stage Type:

Input Impedance:

Maximum Input Level (Screen channels):

Maximum Input Level (Subwoofer channels):

A/D Conversion (Screen channels only):

Surround Channels:

Dataport Outputs

Screen Channels:

Output Attenuation Steps:

Dynamic Range:

THD+N 20 Hz-20 kHz, +12 dBu

Input Level, All Filters Flat:

Frequency Response:

D/A Conversion:

Filter Topology:

Specifications subject to change without notice.

Crossover Filters:

Linkwitz-Riley 24 dB/octave digital filters

 

programmable in approx. 1 Hz steps from

 

150 Hz - 15 kHz

 

Parametric EQ:

Digital bandpass constant Q filter with ±10 dB

 

of boost/cut programmable in approx. 1/10 octave

 

steps from 80 Hz -15 kHz. Q is programmable

 

in 1/10th octave steps from 1/10 to 2 octaves.

CD Horn EQ:

Available on high frequency outputs only

Screen EQ:

Available on high frequency outputs only

Delay:

Programmable in 21 µs steps from 0 to 21 ms

 

per output

 

Polarity:

Normal, Inverted

 

Mute:

Individual mutes on each screen channel output

Subwoofer:

 

 

Output Stage Type:

Single ended (balanced impedance)

Output Attenuation Steps:

0 dB to –18 dB in 3 dB steps

Dynamic Range:

99 dB

 

THD+N 20 Hz-20 kHz, +12 dBu

 

 

Input Level, All Filters Flat:

0.02%

 

Filter Topology:

Digitally controlled analog on DCM-1,

 

DSP on DCM-3

 

High Pass Filter:

Linkwitz-Riley 12 dB/octave filter. Q can be

 

programmed as 0.707 or 2, flat or “step-down”

 

operation

 

Mute:

One mute for all subwoofer outputs

Surround Channels:

Hardwire pass-through from processor input via

 

Surround Insert

 

Output Channels (using the

 

 

Surround Insert connector):

2 or 3 selectable on rear panel

Amplifier A.C. Control

 

 

all amps power on with DCM activation

 

 

Emergency Bypass Crossover

 

 

Filter Type:

1st order Butterworth, 2 or 3 way

Attenuation Range (trimpot):

-6 dB to -24 dB

 

Powered Subwoofer Output

 

 

Output Stage Type:

Single ended (balanced impedance)

Output Impedance:

50Ω

 

Maximum Output Level:

+14.2 dBu (4.0 Vrms)

Loading Requirements (total of

 

 

remote & dataport connection):

RMIN = 2k ohms

CMAX = 4 nF

Hearing Impaired Output

 

 

Output Stage Type:

Single ended (balanced impedance)

Output Impedance:

50Ω

 

Nominal Output Level:

-11.8 dBu (200 mVrms)

Loading Requirements:

RMIN = 2k ohms

CMAX = 4 nF

Surround Insert I / O

 

 

Output Stage Type:

Hardwired connection to processor

 

input connector

 

Input Stage Type:

Hardwired connection to DataPort

 

output connector

 

Monitor Speaker

 

 

Dimensions:

4-inch full range driver

Amplifier Output Power:

10 watt class AB amplifier

Frequency Response:

100 Hz – 8 kHz (±2 dB)

Dynamic Processing:

1.5:1 compression

1675 MacArthur Boulevard • Costa Mesa, CA 92626 • Ph: 800/854-4079 or 714/957-7100 • Fax: 714/754-6174

qscaudio.com

DCM Spec Sheet - 02/23/06