WIRING
Note: This range hood must be properly grounded. The unit should be installed by a qualified electrician in accordance with all applicable national and local electrical codes.
1.Remove the wiring box cover. Remove a knockout from the wiring box.
2.Feed 6" of power cable through the knock- out opening and secure cable to the wiring box with an appropriate connector.
3.Make electrical connections. Connect white to white, black to black and green to green.
4.Replace wiring box cover and screws. Make sure that wires are not pinched between cover and box.
WIRING BOX
COVER
CONNECT DUCTWORK
1.Use 8" round steel duct to connect the duct collar on the hood to the ductwork above.
2.Use duct tape to make all joints secure and air tight.
3.Slide the lower decorative flue section downward, until it fits properly around hood.
4.Secure decorative flue to hood with screws provided.
8”
ROUND
STEEL
DUCT
LOWER
DECORATIVE
FLUE
SECTION