Raypak 133 warranty Raytherm - Type H, Hydronic Heating Boilers, Residential ΠCommercial, Model

Models: 133

1 2
Download 2 pages 11.86 Kb
Page 1
Image 1
Raytherm® - Type H

Job:

 

 

 

 

 

Raytherm® - Type H

Engineer:

 

 

 

 

 

 

Hydronic Heating Boilers

 

 

 

 

 

 

Contractor:

 

 

 

 

 

Residential ΠCommercial

 

 

 

Date:

 

Prepared By:

 

 

Model 133

Model:

 

Indoor/Outdoor:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EFFICIENT

82% thermal efficiency – highest of any atmospheric boiler available today

THERMAL SHOCK PROOF

Twenty-year warranty against thermal shock damage up to 150°F differential

Maximum operating temperature: 230°F

LIGHTWEIGHT

A floor load of 70 lbs./sq. ft. or less

HIGH RECOVERY

Cuts fuel costs substantially because the standby and radiation losses normal to other boilers are eliminated

LOW WATER OPERATING TEMPERATURE

 

 

 

Operates with water temperature as low as 105°F

 

 

 

without condensing

 

 

 

INDOOR MODEL

 

 

 

Heat Exchanger

Gas Train

Construction

ƒ ASME Inspected and Stamped

ƒ Manual Main Gas Shut-off Cock

ƒ

Front Controls

 

160 PSIG

ƒ Main Gas Pressure Regulator

ƒ

Stainless Steel Burners

ƒ

National Board Approved

ƒ Redundant Safety Shut-off Valve

ƒ Polytuf Powder Coat Finish

ƒ Glass-lined Cast Iron Headers

ƒ

Control Valve

ƒ

Vent Selection

ƒ

Copper Finned Tubing

ƒ

Mechanical Modulation (H1)

 

Draft Diverter (Indoor) –

ƒ ASME Steel Tube Sheet

ƒ

Fuel

 

Option D-10

ƒ

Silicone O-Rings

 

Natural Gas

 

Stackless Top (Outdoor) –

ƒ 45 PSIG ASME Pressure Relief

 

Propane Gas

 

Option D-11

 

Valve

ƒ Design Certified ANSI Z21.13/

 

High-Wind Top (Outdoor) –

ƒ Temperature and Pressure Gauge,

 

CSA 4.9

 

Option D-13

 

Shipped Loose

 

 

ƒ

Base – Optional

ƒ

Rear Water Connection

 

 

 

Combustible Floor Shield –

ƒ

Pump – Optional

 

 

 

Option J-1

 

∅,

 

 

ƒ Vent Damper – Indoor Residential

 

Bronze, 1/8 HP, 120 Volt, 1 60 Hz

 

 

 

models only

 

Cast Iron, 1/8 HP, 120 Volt, 1∅,

 

 

 

 

60 Hz

 

 

 

NOTE: Unit cannot be installed

 

 

 

 

 

Controls

 

 

 

outdoors in residential applications.

ƒ120V, 60Hz, 1 Ph Power Supply

ƒ120/24V Transformer

ƒ100% Pilot Shut-off/Lockout

ƒElectronic, Intermittent Ignition (IID) Pilot

ƒHigh Limit Control - Automatic

ƒOn/Off Switch

ƒOperating Limit Control

ƒEconomaster II Pump Time Delay

Catalog No.: 2000.20P

Effective: 12-1-07

Replaces: 4-1-05