XFyre – Type H
Models | Model |
CLEARANCES
| Certified | Recomm. |
| Minimum | Service |
Front | 24” | 24” |
Rear | 24” | 24” |
Right | 1” | 1” |
Left | 1” | 1” |
Top | 12” | 24” |
Floor | 0” | |
Vent | 1” |
Model | MBTUH |
| Dimensions (in.) |
|
| Ship |
| Foot- | Amps* | |||
A | F | G | H | K | N | Weight |
| |||||
|
|
| ||||||||||
|
| Length | Mounting | NPT | NPT | Flue Ø | C/A Ø | (Lbs.) |
| (Ft2) |
| |
Input | Output |
| ||||||||||
300 | 300 | 282 | 3/4 | 4 | 4 | 410 |
| 6.6 | 3 | |||
500 | 500 | 470 | 1 | 4 | 4 | 505 |
| 7.9 | 4 | |||
850 | 850 | 799 | 2 | 6 | 6 | 580 |
| 9.5 | 5 | |||
Ratings shown are for elevations up to 2,000 feet. For installations at elevations | * Current draw is for heater only. |
|
| |||||||||
above 2,000 feet, please consult the factory for additional instructions. |
| (Supply breaker must have delayed trip.) |
|
RATES OF FLOW AND PRESSURE DROPS
Model | 20ºF ∆T | 30ºF ∆T | 40ºF ∆T |
| Min Flow |
| Max Flow |
| |||||||
GPM | ∆P | GPM | ∆P | GPM | ∆P | GPM |
| ∆P |
| ∆T | GPM | ∆P |
| ∆T | |
300 | 28 | 17 | 19 | 8 | 14 | 5 | 14 |
| 5 |
| 40 | 36 | 27 |
| 17 |
500 | 47 | 16 | 31 | 7 | 24 | 4 | 24 |
| 4 |
| 40 | 56 | 24 |
| 18 |
850 | 80 | 40 | 53 | 17 | 40 | 10 | 40 |
| 10 |
| 40 | 80 | 40 |
| 20 |
* Closed systems only
Catalog No.: 2000.17 | Effective: | Replaces: New |