Hi Delta FlexGas – Type H

Hi Delta FlexGas – Type H

Models 302BD-902BD

Model

NOTE: Pump location varies based on model and application

SPECIFICATIONS

 

 

 

 

 

 

 

 

 

 

 

 

Approx.

 

MBTUH

A

B

G

H

K

T

W

Amp.

Shipping

Model

Input

Output

Width

 

Nat

Pro

NPT

 

 

 

Draw*

Wt. (Lbs)

302BD

300

252

36

41

1-1/4

3/4

2

5

6

18

6

405

402BD

399

335

43

41

1-1/4

3/4

2

6

6

18-1/2

6

470

502BD

500

420

50

35-1/2

1-1/4

3/4

2

6

6

22

6

570

652BD

650

546

60-1/2

30-1/2

1-1/4

3/4

2

8

6

27-1/4

6

615

752BD

750

630

67-1/2

27-1/2

1-1/4

1-1/4

2

8

6

30-3/4

6

700

902BD

900

756

78

34-1/2

1-1/4

1-1/4

2

8

6

36

7

765

* Without pump

RATES OF FLOW AND PRESSURE DROPS

Model

10°F ∆T

20°F ∆T

30°F ∆T

 

Min. Flow

 

Max. Flow

 

GPM

∆P (ft)

GPM

∆P (ft)

GPM

∆P (ft)

GPM

∆P (ft)

 

∆T

GPM

∆P (ft)

 

∆T

302BD

51

3.2

25

<1.0

N/A

N/A

20

 

<1

 

25

90

9.8

 

6

402BD

68

5.4

34

1.5

22

<1

20

 

<1

 

34

90

10.0

 

7

502BD

85

9.2

42

2.3

28

1.1

21

 

<1

 

40

90

10.5

 

9

652BD

N/A

N/A

55

4.0

36

1.8

28

 

1.1

 

40

90

10.7

 

12

752BD

N/A

N/A

64

5.5

42

2.5

32

 

1.6

 

40

90

11.0

 

14

902BD

N/A

N/A

76

8.5

51

3.8

38

 

2.2

 

40

90

11.8

 

17

Basis is 20 GPM or 40°F ∆T for minimum flow, 90 GPM for maximum flow.

NOTES:

1.Dimensions are in inches

2.Rates shown are for natural or propane gas, and elevations up to 5,000 feet. For installation above 5,000 feet, please contact manufacturer.

3.Required natural gas supply pressure is 7 - 10.5” WC. Required propane gas supply pressure is 11 - 13” WC.

Raypak, Inc. ƒ 2151 Eastman Avenue, Oxnard, CA 93030 ƒ (805) 278-5300 ƒ Fax (800) 872-9725 ƒ www.raypak.com

Catalog No.: 2000.303A

Effective: 11-15-07

Replaces: 8-15-07

Page 2