Raypak warranty Delta Limited - Type H, Space Heating/Hot Water Boilers, Models 399B-899B

Models: 399B

1 2
Download 2 pages 21.19 Kb
Page 1
Image 1
Delta Limited™ - Type H

Job:

 

 

 

 

 

Delta Limited™ - Type H

Engineer:

 

 

 

 

 

 

Space Heating/Hot Water Boilers

 

 

 

 

 

 

Contractor:

 

 

 

 

 

 

Models 399B-899B

 

 

 

 

 

Prepared By:

 

Date:

 

 

 

 

 

Model:

 

Indoor/Outdoor:

 

MBTUH Input:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100% Factory Fire Tested

Efficiency: 84%

Maximum Outlet Temperature: 230°F
Minimum Non-Condensing Inlet Temperature: 105°F
Thermal Shock Proof Heat Exchanger
Limited Twenty-Year Thermal Shock Warranty
Limited Ten-Year Closed-System Heat Exchanger
Warranty

PolyTuf Powder Coated Cabinet

No Combustible Floor Shield Required

Fan-Assisted

Patented Burner Security Blanket

Shown with outdoor

air inlet and pump covers

Engineer: Proudly Made in the U.S.A

Heat Exchanger

ƒH Stamp

ƒHeaders

Space Heating/Hot Water Boilers Glass-Lined Cast Iron – Standard

Contractor: Bronze – Option A-1

ƒASME Inspected and Stamped 160 PSIG Working Pressure

ƒNational Board Approved

ƒFin Tubing

Models 399B-899B Copper – Standard

Prepared By: Cupro Nickel – Option A-3

ƒASME Steel Tube Sheet

ƒSilicone High Temp O-Rings

ƒPressure Relief Valve, ASME

Date: 45 PSIG – Standard on Model 399B

Model: 60 PSIG – Standard on Models

499B-899B

PSIG – Optional

ƒTemperature and Pressure Gauge

ƒWater Connections

Indoor/Outdoor: Left – Standard

MBTUH Input: Right – Option A-6

Controls

ƒ 120V, 60Hz, 1 Phase Power Supply

ƒ

120/24V 60Hz Transformer

ƒ

100% Shut-Off/Lockout

ƒ

Hot Surface Ignition

ƒ

Remote Flame Sensor

ƒ High Limit Control, Manual Reset

ƒ

On/Off Power Switch

ƒ Manual Shut-Off, Front-Mounted Switch

ƒ

Flow Switch

ƒ Blocked Vent Pressure Switch

ƒ Combustion Air Proving Switch

ƒ Pump Time Delay Relay

Gas Train

ƒManual Gas Shut-Off Valve(s)

ƒCombination Valves

ƒFiring Mode

100% Factory Fire Tested On/Off: Model 399B

Maximum Outlet Temperature: 230°F 2-Stage: Models 499B-899B

ƒFuel

Minimum Non-Condensing Inlet Temperature: 105°F Natural Gas

Thermal Shock Proof Heat Exchanger Propane Gas

ƒDesign Certified - ANSI Z21.13/CSA 4.9

Burner

ƒUltra-Low NOx: Less than 20 PPM

Construction

ƒIndoor/Outdoor Construction

ƒEnclosed Front Controls

Venting

ƒVent Location

Limited Twenty-Year Thermal Shock Warranty Top, Outdoor – Standard

Limited Ten-Year Closed-System Heat Exchanger Top, Indoor – Option D-20

Warranty Rear – Option D-14

ƒVent Termination Cap

No Combustible Floor Shield Required Outdoor D-11

Patented Burner Security Blanket Indoor, Horizontal D-15

Heat Exchanger Indoor, Vertical (by others)

ƒExtractor – Optional

Controls By others

Gas Train Not required

Temperature Controls

 

 

 

 

B-2

Tankstat, Single-Stage

 

 

 

(100-200°F)

 

 

 

 

B-3

Tankstat, 2-Stage (100-200°F)

B-6

Aquastat, 2-Stage (100-200°F)

B-__

TempTracker Digital Controller,

 

 

 

2-Stage (Loose)

 

 

B-__

TempTracker Digital Controller,

 

 

 

4-Stage (Loose)

 

 

Options

 

 

 

 

 

 

 

C-6

Ignition Module, Manual Reset

F-10

Low Water Cut-Off, Remote Probe

I-1

High Limit Control, Auto Reset

P-

 

 

Pump:

 

 

HP, 120V, 1, 60Hz

 

 

 

Water Hardness:

 

 

GPG

 

 

 

Cast Iron

 

 

Bronze

 

 

 

Mounted

 

 

Loose

 

 

 

Front

 

 

Rear

P-26

Cold Water Start (See 2000.48)

S-1

Low Gas Pressure Switch, Manual

S-2

High Gas Pressure Switch,

 

 

 

Manual

 

 

 

 

X-1

SureRack™ Kit

 

 

X-2

SureRack Add-on

 

 

Regulatory Agency Requirements

ƒ Status Display Lights

Delta Limited models not approved for use in California

Catalog No.: 2000.461A

Effective: 07-21-10

Replaces: 9-15-07

Page 1
Image 1
Raypak warranty Delta Limited - Type H, Space Heating/Hot Water Boilers, Models 399B-899B, Engineer, Contractor, Date