Raypak 514-824 manual Operating Instructions, To Turn Off Gas To Appliance, For Models

Models: 514-824

1 32
Download 32 pages 11.75 Kb
Page 5
Image 5
OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Set the thermostat on the lowest setting.

3.Turn off all electric power to the appliance.

4.Remove heater door panel.

5.This appliance is equipped with an ignition device which automatically light the pilot. Do not try to light the pilot by hand.

6.For Models 514-724 with Honeywell Gas Valve. Push in gas control knob slightly and turn clockwise

For Models 514-724 with Robertshaw Gas Valve. to “OFF”. Knob cannot be turned to “OFF” unless knob is pushed in slightly. Do not Force.

GAS CONTROL KNOB

SHOWN IN “ON”

POSITION

GAS INLET

Fig. #8219.0

For Models 514-724 with Robertshaw Gas Valve.

Turn Gas control knob clockwise For Models 824 to “OFF”.

GAS CONTROL

KNOB SHOWN

IN “ON” POSITIONS

GAS INLET

Fig. # 8080.0

For Models 824

Turn main gas shut-off and pilot shut-off valves counter

clockwise 8.For Models 514-724 to “OFF”.

PILOT SHUT-OFF

TO PILOT

 

VALVE CONTROL

MAIN GAS SHUT-OFF

SHOWN IN THE

VALVE SHOWN IN

“ON” POSITION

THE “ON” POSITION

GAS

 

INLET

 

 

Fig. # 8220.0

7.Wait fire (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above on this label. If you don't smell gas, go to the next step

8.For Models 514-724

Turn gas control knob counter clockwise to “On”

For Model 824

Turn main gas shut-off and pilot shut-off valves

clockwise For Model 824 to on.

9. Replace heater door panel.

10.Turn on all electric power to the appliance.

11.Set thermostat to desired setting.

12.If the appliance will not operate, follow the instruc- tions “To Turn Off Gas to Appliance” and call your service technician or gas supplier.

TO TURN OFF GAS TO APPLIANCE

1.Set the thermostat to the lowest setting.

2.Turn off all the electric power to the appliance if service is to be performed.

3.Remove heater door panel.

4.For Models 514-724

Push in gas control knob slightly and turn clock-

wise TO TURN OFF GAS TO APPLIANCE to “OFF”.

For Models 824

Turn main gas shut-off and pilot shut-off valves

counter clockwise 4.For Models 514-724 to “OFF”.

5. Replace heater door panel.

5

Page 5
Image 5
Raypak 514-824 manual Operating Instructions, To Turn Off Gas To Appliance, For Models 514-724with Robertshaw Gas Valve