OPERATING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Set the thermostat on the lowest setting.

3.Turn off all electric power to the appliance.

4.Remove heater door panel.

5.This appliance is equipped with an ignition device which automatically light the pilot. Do not try to light the pilot by hand.

6.For Models 514-724 with Honeywell Gas Valve. Push in gas control knob slightly and turn clockwise

to “OFF”. Knob cannot be turned to “OFF” unless knob is pushed in slightly. Do not Force.

GAS CONTROL KNOB

SHOWN IN “ON”

POSITION

GAS INLET

Fig. #8219.0

For Models 514-724 with Robertshaw Gas Valve.

Turn Gas control knob clockwise to “OFF”.

GAS CONTROL

KNOB SHOWN

IN “ON” POSITIONS

GAS INLET

Fig. # 8080.0

For Models 824

Turn main gas shut-off and pilot shut-off valves counter

clockwise to “OFF”.

PILOT SHUT-OFF

TO PILOT

 

VALVE CONTROL

MAIN GAS SHUT-OFF

SHOWN IN THE

VALVE SHOWN IN

“ON” POSITION

THE “ON” POSITION

GAS

 

INLET

 

 

Fig. # 8220.0

7.Wait fire (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above on this label. If you don't smell gas, go to the next step

8.For Models 514-724

Turn gas control knob counter clockwise to “On”

For Model 824

Turn main gas shut-off and pilot shut-off valves

clockwise to on.

9. Replace heater door panel.

10.Turn on all electric power to the appliance.

11.Set thermostat to desired setting.

12.If the appliance will not operate, follow the instruc- tions “To Turn Off Gas to Appliance” and call your service technician or gas supplier.

TO TURN OFF GAS TO APPLIANCE

1.Set the thermostat to the lowest setting.

2.Turn off all the electric power to the appliance if service is to be performed.

3.Remove heater door panel.

4.For Models 514-724

Push in gas control knob slightly and turn clock-

wise to “OFF”.

For Models 824

Turn main gas shut-off and pilot shut-off valves

counter clockwise to “OFF”.

5. Replace heater door panel.

5

Page 5
Image 5
Raypak 514-824 manual Operating Instructions, To Turn OFF GAS to Appliance

514-824 specifications

The Raypak 514-824 is a leading model in the realm of heating solutions, specifically designed for outdoor residential and commercial applications. Known for its efficiency and durability, the Raypak 514-824 has gained popularity among users looking for reliable heating systems.

One of the standout features of the Raypak 514-824 is its advanced design that incorporates high-quality materials ensuring longevity. This model is constructed with a robust heat exchanger, typically made of copper or bronze, which promotes better thermal conductivity while resisting corrosion. This ensures that the unit maintains a high performance level even after prolonged use, making it an excellent choice for areas with varying weather conditions.

The technological aspects of the Raypak 514-824 are also impressive. It is equipped with an intuitive digital control system that allows for precise temperature adjustments. Users can easily set their desired temperature, which is maintained automatically, providing comfort with minimal manual control. The digital display is user-friendly, making it simple to monitor system performance and adjust settings as needed.

Efficiency is a critical characteristic of the Raypak 514-824. With a focus on energy-saving capabilities, this heater exceeds industry standards, often achieving efficiency ratings that minimize energy consumption. This not only results in cost savings on utility bills but also contributes to environmental sustainability, making it a more responsible choice for heating needs.

Safety features are paramount in the design of the Raypak 514-824. It includes various protections such as high-limit switches and pressure regulators that help prevent overheating and maintain optimal operating conditions. These safety measures ensure that the unit operates reliably and minimizes risks associated with traditional heating systems.

Furthermore, installation versatility sets the Raypak 514-824 apart. It is designed for straightforward installation, suitable for various setups whether it's integrated with a swimming pool or spa heating system. This adaptability makes it an ideal selection for anyone looking to enhance their outdoor space with effective heating solutions.

In summary, the Raypak 514-824 is a high-performing, efficient, and versatile heating model that combines modern technology with significant safety features. Its emphasis on user-friendly operation and long-lasting materials makes it a top contender in the heating market, catering to both residential and commercial applications. The Raypak 514-824 exemplifies a commitment to quality, efficiency, and reliability.